100
Installation and Maintenance
Service Manual
Procedure
Step
Holder
Circlip
Wire clip
Screws
Soft sheath
Connecto
r
coPowerrd
Rotate the electric box assy. Twist offthe screws
that are locking the wire clip and loosen the
power cord. Remove the wiring terminal of
power cord. Lift up the main board and take it off.
9.Remove evaporator assy
First remove the left side of evaporator from
the groove on the rear case assy. Then
remove the right side from the clasp on the
rear case assy.
Clasp
Rear case assy
Groove
a
c
b
c
Rotate the electric box assy. Twist offthe
screwsthat are locking the wire clip and
loosen the power cord. Remove the wiring
terminal of power cord. Lift up the main
board and take it off.
Instruction:Some wiring terminal of this
products is with lock catch and other
devices.The pulling method is as below:
Remove the soft sheath for some
terminals at rst, hold the circlip and then
pull out the terminals,
Pull out the holder for some terminals at
rst(holder is not available for some wiring
terminal).hold the connector and then pull
the terminal.
Remove 3 screws xing evaporator assy.
At the back of the unit, remove the screw
xing connection pipe clamp and then
remove the connection pipe clamp.
First remove the left side of evaporator from
the groove on the rear case assy. Then
remove the right side from the clasp on the
rear case assy.

Table of Contents