NOTICE
●
The power cord and control wire can't be crossed or
winding.
●
The drain hose should be bound at the bottom.
NOTICE
●
The wiring board is for reference only, please refer
to the actual one.
3.
connection pipe
drain hose
band
2 3
black
Outdoor unit connection
1. Put the bound pipes in the wall pipe and then
5. Check if the indoor unit is installed firmly and
upper hook
indoor unit
band
lower hook of
wall-mounting frame
2.
21
Do not bend the drain hose too excessively in order
to prevent blocking.
indoor power cord
3.
N(1)
4.
white
(blue)
red
(brown)
green
(yellow-green)
Hang the indoor unit
Step 9:
Remove the wire clip; connect the power conn-
ection wire to the wiring terminal according to
the color; tighten the screw and then fix the po-
wer connection wire with wire clip.
Bind them evenly.
The liquid pipe and gas pipe should be bo-
und separately at the end.
closed to the wall.
indoor
wall pipe
2.
3.
4.
4.
outdoor
5.
sealing gum
gas
pipe
liquid pipe
drain hose
●
indoor and
outdoor power cord
drain hose with the band.
Step 8:
Bind up pipe
1. Bind up the connection pipe, power cord and
NOTICE
Reserve a certain length of drain hose and
power cord for installation when binding th-
em. When binding to a certain degree, sep-
arate the indoor power and then separate
the drain hose.
WARNING
Communication cables should be laid out through
cabling trough, conduit tube or cable channel;
otherwise, it may cause electric shock or death.
make them pass through the wall hole.
Hang the indoor unit on the wall-mounting
frame.
Stuff the gap between pipes and wall hole
with sealing gum.
Fix the wall pipe.
Put wiring cover back and then tighten the screw.
Close the panel.