Installation Manual
27
7.3 Install Indoor Unit
7.3.1 Installation of Mounting Plate
1.Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way type, during installation, the
indoor unit should slightly slant to water tray's outlet for smooth drainage of condensate.
2.Fix the mounting plate on the wall with screws.
3.Be sure that the mounting plate has been xed rmly enough to withstand about 60 kg. Meanwhile, the weight should be evenly
shared by each screw.
1.Slant the piping hole (Φ55) on the wall slightly downward to the outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring
from being damaged when passing through the hole.
7.3.2 Drill Piping Hole
7.3.3 Installation of Drain Hose
1.Connect the drain hose to the outlet pipe of the indoor unit.Bind the joint with
rubber belt.
2.Put the drain hose into insulating tube.
3.Wrap the insulating tube with wide rubber belt from the joint of outlet pipe and
insulating pipe so as to prevent shift of insulating tube. The drain hose should be
placed at a downward slant for easy discharge of condensate.
Note: the insulating tube should be connected reliably with the sleve outside the
outlet pipe. The drain hose should be downward slant, without distortion, bulge or
uctuation. Do not put the water outlet in the water.
1.Open the front panel.
2.Remove the wiring cover.Connect and x power connection cord and signal control wire to the terminal board. As shown in Fig.2.
3.Make the power connection cord and signal control wire through the hole in the back of indoor unit.
4.Reinstall the cord anchorage and wiring cover.
5.Reinstall the front panel.
7.3.4 Connecting Indoor and Outdoor Electric Wires