59
Installation and Maintenance
Service Manual
No. Name No. Name
1 Indoor unit 8 Sealing gum
2 Outdoor unit 9 Wrapping tape
3 Connection pipe 10
Support of outdoor 
unit
4 Drainage pipe 11 Fixing screw
5
Wall-mounting 
frame
12
Drainage plug(cooling 
and heating unit)
6
Connecting 
cable(power cord)
13
Owner’s manual, 
remote controller
7 Wall pipe
1. Safety Precaution
(1) Must follow the electric safety  regulations when installing 
the unit.
(2) According  to  the local safety  regulations,  use qualified 
power supply circuit and air switch.
(3) Make sure the power supply matches with the requirement 
of air  conditioner.  Unstable power supply  or incorrect wiring 
may result in electric shock,re hazard or malfunction. Please 
install  proper  power  supply  cables  before  using  the  air 
conditioner.
(4) Properly connect the live  wire, neutral wire and grounding 
wire of power socket.
(5) Be sure to cut off the power supply before proceeding any 
work related to electricity and safety.
(6) Do not put through the power before nishing installation.
(7)  For appliances  with  type Y attachment,the  instructions 
shall contain the substance of thefollowing.If the supply cord is 
damaged,it must be  replaced by the manufacturer,its service 
agent or similarly qualied persons in order to avoid a hazard.
(8) The temperature of refrigerant  circuit will be  high, please 
keep the interconnection cable away from the copper tube.
(9) The appliance shall be installed in accordance with national 
wiring regulations.
(10) Appliance  shall be  installed,  operated and  stored in  a 
room with a oor area larger than 4m.
8.2 Installation Parts-checking 
8.3 Selection of Installation Location
8.4 Electric Connection Requirement
8.5 Installation of Indoor Unit
Air-conditioner Air switch capacity
18K 16A
1. Please contact the local agent for installation.
2. Don't use unqualied power cord.
1. Basic Requirement:
Installing the unit in the following places may cause 
malfunction. If it is unavoidable, please consult the local dealer:
(1) The place with strong  heat sources, vapors, ammable or 
explosive gas, or volatile objects spread in the air.
(2) The place with high-frequency  devices (such  as welding 
machine, medical equipment).
(3) The place near coast area.
(4) The place with oil or fumes in the air. 
(5) The place with sulfureted gas.
(6) Other places with special circumstances.
(7) The appliance shall nost be installed in the laundry.
2. Grounding Requirement:
(1) The air conditioner is  rst class electric appliance. It must 
be  properly  grounding  with  specialized  grounding  device 
by a professional.  Please make  sure it  is  always grounded 
effectively, otherwise it may cause electric shock.
(2) The yellow-green wire in air  conditioner is  grounding wire, 
which can't be used for other purposes.
(3) The  grounding  resistance  should  comply with  national 
electric safety regulations.
(4)  The appliance must be  positioned  so  that  the  plug  is 
accessible.
(5) An all-pole disconnection switch having a contact separation 
of at least 3mm in all poles should be connected in xed wiring.
(6) Including an  air switch with suitable  capacity,  please note    
the  following  table. Air  switch  should  be  included magnet 
buckle and  heating buckle function, it can protect the  circuit-
short and overload. (Caution: please do not use the fuse only 
for protect the circuit)
1. Choosing Installation Iocation
Recommend  the installation  location  to the  client  and then 
conrm it with the client.
2. Indoor Unit:
(1) There should be no obstruction near air inlet and air outlet.
(2) Select  a location  where the  condensation water  can be 
dispersed easily andwon't affect other people.
(3)  Select  a  location  which  is  convenient  to  connect  the 
outdoor unit and near the power socket.
(4) Select a location which is out of reach for children.
(5) 
The  location should be  able  to withstand
  the weight of 
indoor unit and won't increase noise and vibration.
(6) 
The appliance must be installed 2.5m above oor.
(7)  Don't  install  the  indoor  unit  right  above  the  electric 
appliance.
(8) Please try your best to keep way from uorescent lamp.
3. Outdoor Unit:
(1) Select a location where the noise and outow air emitted by 
the outdoor unit will not affect neighborhood.
(2) The location should be well ventilated and dry, in which the 
outdoor unit  won't be  exposed directly  to sunlight  or strong 
wind.
(3) The  location should be  able to  withstand  the weight  of 
outdoor unit.
(4) Make sure that  the installation follows the requirement of 
installation dimension diagram.
(5) Select a location which is out of reach for children and far 
away from  animals or plants.If  it is unavoidable, please add 
fence for safety purpose.
Note:
Please  notice  that  the  unit  is  filled  with 
ammable gas R32. Inappropriate treatment of 
the unit involves the risk of severe damages of 
people and material. Details to this refrigerant 
are found in chapter “refrigerant”.