Climber 10/ Translation of the original instructions
LUBRICATION POINTS (every 40 hours)
TROUBLE-SHOOTING
PROBLEM
CAUSE REMEDY
Dashboard OFF with key in “AVV.” (ON) pos.
– Battery not supplying power – Check connecting cables
– Recharge battery
– Change the fuse
Dashboard ON, but starter does not turn over with key in “AVV” (ON) pos.
– Battery not supplying enough power – Recharge battery
– Start-up go-ahead not given – Travel lever in stop position
– Disengage blades
– Sit in the driver’s seat
Difficult starting or engine running irregularly
– Carburation problems – Clean or replace the air filter
– Adjust the carburettor (follow engine manual
instructions)
– Deposits or dirt in fuel – Empty the tank and use fresh petrol
– Check and change the petrol filter if
necessary
Starter turns over but engine does not start
– No petrol flow – Check that the choke has been activated
– Check petrol level in tank