TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
SMELL OF GAS SHUT OFF LP GAS CYLINDER VALVE AT ONCE.
DO NOT USE THE APPLIANCE UNTIL LEAK IS SEALED.
Leak detected at cylinder, regulator or
other connection.
1. Regulator fitting loose. 1. Tighten fitting and "Leak Test".
2. Gas leak in hose/regulator or control
valves.
2. See authorized service centre.
Flame flashback beneath control panel. 1. Venturi blocked. 1. Remove burner, clean venturi. See
"Venturi Tube".
Burner will not light. 1. Out of LP Gas. 1. Refill LP Gas Cylinder.
2. Igniter wire not connected. 2. Connect electrode wires to burner.
3. Igniter electrode misaligned on
burner.
3. Realign electrode.
4. Igniter malfunctions. 4. Use "Manual Lighting" Procedure.
5. Regulator is not fully connected to the
cylinder valve.
5. Tighten the regulator hand wheel.
6. Burner valve left open while cylinder
valve was opened causing the Flow
Limiting Device to activate.
6. Close burner and cylinder valves.
Open cylinder valve slowly, then open
burner valve to light.
7. A leak in the system causing the Flow
Limiting Device to activate.
7. Leak test connections to determine
loose fitting. Tighten fitting. Leak test
system.
8. Venturi blocked. 8. Remove burner, clean venturi. See
"Venturi Tubes".
9. Venturi not aligned with valve orifice. 9. Realign venturi to orifice. See
"Venturi Tube".
10. Orifice blocked. 10. Remove burner, clean orifice with a
pin or fine wire. Do not attempt to drill
orifice.
11. Hose is twisted. 11. Straighten hose. Keep away from
bottom casting.
Decreasing heat, "popping sound". 1. Out of LP Gas. 1. Refill LP Gas Cylinder.
2. Venturi blocked. 2. Remove burner, clean venturi. See
"Venturi Tube".
"Flare-ups" or grease fires. 1. Excessive grease buildup. 1. See "Maintenance".
2. Excessive heat. 2. Turn burner control to a lower setting.
Humming noise from regulator. 1. Cylinder valve turned on too quickly. 1. Turn cylinder valve on slowly.
Yellow Flame. 1. Some yellow flame is normal. If it
becomes excessive the venturi may
be blocked.
1. Remove burner, clean venturi. See
"Venturi Tube".
2. Burner ports blocked. 2. Remove burner & clean with soft
bristle brush.
Inside of cabinet appears to be peeling. 1. This is a build up of grease. The
inside of the lid is not painted.
1. Clean with stiff bristle brush or
scraper.
13