Maintenance
The VRC-3E and VRC-6E Steamers are designed
for minimum maintenance, and no user adjustments
should be necessary. Certain parts may need
replacement after prolonged use. If there is a need
for service, only authorized Groen representatives
should perform the work.
If steam or condensate is seen leaking from around
the door, take the following steps:
1. Check the door gasket. Replace it if it is cracked
or split.
2. Inspect the cooking chamber exhaust to be sure
it is not blocked.
3. Adjust the door latch pin to allow for changes
that might occur as the gasket ages.
a. Loosen the lock nut at the base of the latch
pin, then turn the latch pin ¼ turn clockwise,
and tighten the lock nut.
b. After adjustment, run the unit to test for
further steam leakage.
c. If there is still leakage, repeat the
adjustment.
d. Continue adjusting the pin clockwise until the
door fits tightly enough to prevent leakage.
Troubleshooting
This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following
is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel.
SYMPTOM WHO WHAT TO CHECK
1. No power User a. Check wall circuit breaker.
b. Disconnect power, then check fuses on back of steamer.
c. Call for service technician.
2. Reset light is on User a. Momentarily turn the drain valve to open then back to
closed to reset.
b. Call for service technician.
3. Any unusual operation User a. Press ON/OFF pad to turn steamer off. Press again to turn
steamer on.
b. Call for service technician.
4. No steam User a. Check and add water as required. (For auto fill units turn
unit off and on)
b. Ensure door is closed.
c. Call for service technician.
5. Door pops open User a. Ensure drain and vent are not plugged. No more than two
units should be attached to a single drain line.
b. Check door pin adjustment per above.
c. Call for service technician.
6. HI TEMP Light is ON User a. Wait 30 minutes for the unit to cool down, RESET light
should come on when unit has cooled. Turn unit on.
Momentarily turn drain valve to reset safety circuit.
b. Call for Service Technician.
7. Dial gage will not read
212
User a. This may be normal, altitude and water purity may affect
temperature reading on the gage.

Other manuals for Groen Vortex VRC-3E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Groen Vortex VRC-3E and is the answer not in the manual?

Groen Vortex VRC-3E Specifications

General IconGeneral
BrandGroen
ModelVortex VRC-3E
CategoryElectric Steamer
LanguageEnglish

Related product manuals