53
54
Model
10000TL3-S 11000TL3-S 12000TL3
Specification
Input data
Max. DC power
12000W 14400W
14400W
Max. DC voltage
1000V 1000V 1100V
Start Voltage
160V 160V 160V
PV voltage range
160V-1000V 160V-1000V 160V-1000V
MPP voltage range/
DC nominal voltage
200V-1000V /600V
Max. PV Isc
16A/16A 16A/16A 16A/16A
Number of independent
MPP trackers/strings per
MPP tracker
2/1+12/1+12/1+1
Full load voltage
range
450V-850V
450V-850V 550V-850V
Max. input current
13A/13A 13A/13A 11.5A/11.5A
Backfeed current
0A 0A 0A
Output (AC)
Inrush current <15A
<15A
<15A
Max output fault
current
Max output overload
protection
Nominal AC voltage
range
AC grid frequency 50/60Hz 50/60Hz 50/60Hz
AC grid frequency range
44-55Hz/54-65Hz
Nominal AC voltage 230V/400V
230V/400V
230V/400V
Max. output current
16.7A
18.3A
19A
Rated AC output power
10kW 11kW
12kW
Max AC apparent power
11kVA
12.1kVA 13.2kVA
33A
33A
44A
25A
25A
25A
184~300V
184~300V
184~275V
Efficiency
Max efficiency
98.3% 98.3%
Euro-eta
98% 97.8%
MPPT efficiency
99.5% 99.5%
Power factor at rated power
1
1 1
Adjustable displacement
power factor
THDi @Full load&THDv<1%
0.8leading - 0.8laging
AC grid connection type
<3%
<3% <3%
3W+N+PE
3W+N+PE 3/N/PE
Protection devices
DC reverse polarity
protection
yes yes yes
DC switch for each MPPT
yes yes yes
Output AC overcurrent
protection
yes yes yes
Output AC overvoltage
Protection - Varistor
yes yes yes
Ground fault monitoring
yes yes yes
Grid monitoring
yes yes yes
Integrated all-pole
sensitive
leakage current
monitoring unit
yes yes yes
General Data
Dimensions(W/H/D)
in mm
Weight
Operating
temperature range
25 °C ... +60 °C
(13 °F ... +140 °F)
With derating above 45 °C(113 °F)
Noise emission (typical) 35 dB(A)
480*448*200
22kg 22kg 23.5kg
Altitude 3000m
98.3%
98%
99.5%