Growatt 10000UE
Growatt 12000UE
Growatt 18000UE
Growatt 20000UE
Installation
&
Operation Manual
GROWATT NEW ENERGY CO., LTD
No.12 Building, Xicheng Industrial
Zone, Bao’an District, Shenzhen, P. R.China
+ 86 755 2747 1900
+ 86 755 2749 1460
service@ginverter.com
www.ginverter.com
T
F
E
W

Other manuals for Growatt 10000UE

Question and Answer IconNeed help?

Do you have a question about the Growatt 10000UE and is the answer not in the manual?

Growatt 10000UE Specifications

General IconGeneral
ModelGrowatt 10000UE
Rated Power10000W
Number of MPP Trackers2
AC Nominal Power10000W
AC Grid Frequency50/60Hz
AC Output Frequency50/60Hz
THDi<3%
DC SwitchYes
Protection DegreeIP65
TopologyTransformerless
Efficiency (Max.)98.4%
Peak Efficiency98.4%
MPPT Voltage Range200-1000V
MPPT Range200-1000V
Nominal AC Voltage230V
AC Output Voltage230V
AC Voltage Range180-280V
Power Factor0.8 leading to 0.8 lagging
Protection ClassI
Operating Temperature Range-25°C to 60°C
CoolingFan
CommunicationWiFi/GPRS

Summary

Introduction

Product Overview

Details the Growatt UE series inverters as grid-tied, three-phase, multi-string inverters with multi-MPP trackers.

LCD display

General LCD display

Describes the LCD display for checking status, historical data, and setting parameters via knock operations.

COMMUNICATIONS

ShineNet monitoring software

PC software for collecting and analyzing Growatt inverter data, allowing real-time monitoring and history analysis.

TROUBLE SHOOTING

Error Messages displayed on LCD

Explains that error messages appear on the LCD screen for system and inverter faults, aiding diagnosis.

Safety

Grounding the PV generator

Instructions for complying with local requirements for grounding PV modules and generators for optimal protection.

Safety Standards Compliance

Growatt UE is designed to meet various safety standards worldwide, including VDE0126-1-1, AS4777, and DK5940.

Unpacking

Unpacking and Inspection

Provides instructions for checking the Growatt UE inverter for completeness and external damages after opening the packing box.

Information of Label

Details the information contained on the inverter's label, including model name, certificates, and specifications.

Mounting

Selecting Mounting Location

Guidance for choosing a suitable installation location, emphasizing wall strength and clearance requirements.

Dimensions and Clearances

Dimensions and Required Clearances

Provides dimensions (Height, Width, Depth) and weights for different Growatt UE inverter models.

Minimum Clearances Diagram

Illustrates the necessary minimum clearances around the inverter for proper operation and ventilation.

Mounting the Bracket

Mounting the Bracket

Describes the initial step of firmly mounting the bracket to the wall before installing the inverter.

Mounting Inverter

Mounting Inverter

Details how to lift and hang the inverter onto the mounted bracket using handles and matching hooks.

Electrical connections

Wiring AC Output

Provides instructions for wiring the AC output, including measuring grid voltage and frequency, and opening the breaker.

Cable requirements

AC Output Cable Specifications

Lists cable requirements (mm, Area mm², AWG no.) for different Growatt UE inverter models.

Connector Interface Details

Shows the interface of the connector and instructions for connecting cables to bolts.

Wiring DC Input

Wiring DC Input

Specifies the maximum open circuit voltage for strings and the maximum length for DC wiring.

DC Connection Diagram

Illustrates the DC side connection, highlighting paired male/female connectors for PV arrays and inverters.

Commissioning

Inverter Connection and Initial Display

Describes the inverter's display and LED status when connected to PV arrays and AC grid.

System Operation After AC Connection

Explains the system operation after turning on the AC breaker, including LCD display and LED status.

Operation Modes

Normal Mode

Details the normal operation mode where the inverter functions correctly and the LED turns green.

Fault Mode

Fault Mode

Describes the fault mode where the inverter's controller monitors for faults, displaying information on the LCD and turning the LED red.

Shutdown Mode

Shutdown Mode

Explains that inverters stop running in low sunlight, with LCD and LED turning off.

LCD display

Power on display

Details the initial LCD display when the inverter is powered on, showing the Growatt Logo.

LCD Display Overview

State, Input, Output, Power Line Information

Describes the main display interfaces showing inverter status, input parameters, output parameters, and power line details.

Working History, Property, Setting Menus

Outlines the navigation paths to access working history, property settings, and general settings menus.

LCD Display Details

LCD Display when background light off

Details the four interfaces displayed when the background light is off, including running status and input/output info.

Interface 1: Running status

Displays inverter status, error codes, energy generated today, and total energy generated since installation.

Interface 2: Input information

Shows PV input parameters like voltage, current, and power for each MPP tracker.

Interface 3: Output information

Provides output details including voltage, current, and power for each phase.

Operate by knock

Knock type and definition

Defines the three types of knock operations (single, double, thrice) and their corresponding functions.

Light background light and single knock

Explains how to use knocks to light the background and check running information.

Data checking and parameters setting

First level menu

Describes how to enter the first level menu using a thrice knock and navigate through items with a single knock.

Second level menu

Explains navigation within the second level menu, moving between items with a single knock and entering sub-menus with a double knock.

Third level menu and explanations

Working information

Details the third level menu interfaces for working information, covering state, input, output, and power line data.

Working information sub-items explanation

Provides explanations for sub-items within the working information section, detailing inverter status and energy production.

Historical information

Historical information

Details the third level menu interfaces for historical information, including error records and energy generation.

Historical information sub-items explanation

Explains sub-items for historical information, including error records, daily, monthly, and yearly energy generation.

Property information

Property information

Shows the second level menu interface for property information, including serial number, model, and firmware versions.

Parameters set and auto test

Set inverter's COM address

Instructions for setting the inverter's COM address, either randomly or fixed, for communication.

Set language

Guides users on changing the inverter's display language, listing available languages and their sequence numbers.

Set inverter time

Set inverter time

Details the process for setting the inverter's system time parameters: year, month, day, hour, and minute.

Auto test function

Auto test function

Explains how to run the auto test function to check inverter protection against abnormal grid conditions.

Inverter faulty messages

System fault message display

Lists system fault messages that may appear on the LCD and provides explanations and suggestions for each.

Error message

Covers inverter errors originating from internal components, listing display messages and their operations/suggestions.

Trouble shooting

General question

Provides a resource for general inquiries by directing users to the Q&A column on the Growatt website.

Error Messages displayed on LCD

System fault

Details system faults caused by external factors like wiring or grid issues, providing error messages and suggestions.

Inverter fault

Inverter fault

Lists inverter faults caused by internal components, providing error codes, meanings, and suggestions for resolution.

Specifications

Input Data Specifications

Presents input data specifications including DC power, voltage, current, and MPP trackers for various inverter models.

Growatt Factory warranty

Warranted products

Lists the specific Growatt inverter products covered by the factory warranty.

Limited Product Warranty

Warranty Terms and Conditions

Outlines the terms of the limited product warranty, including duration, exclusions, and limitations of liability.

Warranty conditions

Exclusions from Limited Product Warranties

Lists conditions and actions that void the Growatt inverter warranty, such as misuse or improper installation.

Liability Limitations

Defines Growatt's liability limits regarding defects, excluding indirect damages and loss of profit.

Contact

Information for Technical Inquiries

Specifies the information required when contacting Growatt or an installer for technical support.

Related product manuals