Do you have a question about the Growatt SPH 10000TL3 BH and is the answer not in the manual?
Model | SPH 10000TL3 BH |
---|---|
Category | Inverter |
Max. DC Voltage | 1000 V |
Nominal DC Voltage | 600 V |
Number of MPPTs | 2 |
Nominal AC Output Power | 10000 W |
AC Nominal Voltage | 230 V / 400 V |
Frequency | 50/60 Hz |
Total Harmonic Distortion (THD) | <3% |
DC Connection Type | MC4 |
Protection Degree | IP65 |
Topology | Transformerless |
Operating Temperature Range | -25°C to +60°C |
Noise Level | <30 dB |
Cooling Method | Natural Convection |
MPPT Voltage Range | 200 V - 950 V |
Max. AC Output Power | 11000 VA |
AC Voltage Range | 180-280V |
Humidity | 0 to 100% (Non-condensing) |
Power Factor | >0.99 (Adjustable 0.8 leading - 0.8 lagging) |
Details essential safety precautions for handling high voltage and equipment.
Specifies location, materials, and environmental conditions for SPH installation.
Lists required tools and explains the LAN line wiring sequence.
Step-by-step guide for physically mounting the SPH inverter on a wall.
Instructions for connecting the PV input terminals using MC4 connectors.
Details connecting AC output and off-grid terminals for grid/backup power.
Guide for connecting the battery terminals using MC4 connectors.
Instructions for connecting the meter terminal for energy flow monitoring.
Details grounding requirements for the SPH inverter.
Steps for electrifying and commissioning the SPH inverter after installation.
Explains the different operating modes of the SPH inverter.
Details the normal operation states including online and backup modes.
Describes how the SPH handles and displays system or machine faults.
Guide to configuring various operating modes of the SPH inverter.
Step-by-step guide to starting up the SPH inverter.
Procedure for safely disconnecting and shutting down the SPH system.
Lists common error messages and their suggested solutions.