EasyManua.ls Logo

Growatt SPF5000 - User Manual

Growatt SPF5000
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation
&
Operation Manual
No.28 Guangming Road, Shiyan Street, Bao'an District, Shenzhen,
Shenzhen,P.R.China
+ 86 755 2747 1942
service@ginverter.com
www.ginverter.com
T
E
W
GR - UM - 127 - A - 01
Installation Manual Of PV Off-grid Inverter
SHENZHEN GROWATT NEW ENERGY TECHNOLOGY CO.,LTD

Questions and Answers

  • S
    Sarah WhiteAug 9, 2025
    Why Growatt Inverter has no response after power on?
    • S
      Samantha CampbellAug 9, 2025
      If your Growatt Inverter doesn't respond after powering it on, it could be due to: * Very low battery voltage. Check the batteries and wiring connections. * Reversed battery polarity. Re-charge the battery. * A faulty battery. Replace the battery.
  • L
    Lauren GarzaAug 17, 2025
    What to do if my Growatt SPF5000 shows 'UTI out end'?
    • C
      Christopher James PhDAug 17, 2025
      If the Growatt Inverter displays 'UTI out end', it could be due to several reasons: * The input protector may be tripped, so check the AC breaker and wiring. * The AC power quality might be insufficient; inspect the AC wires for proper thickness and length. * If using a generator, ensure it's functioning correctly and the input voltage range setting is correct. * Try setting the output source priority to 'Solar First'. * Alternatively, change the output source priority to 'Utility first'.
  • P
    pattersonkevinAug 25, 2025
    Why does my Growatt SPF5000 Inverter shut down automatically during startup?
    • H
      hamptonlaurieAug 25, 2025
      If your Growatt Inverter shuts down automatically during startup, it's likely due to: * Low battery voltage. Try re-charging the battery. * A faulty battery. In this case, replace the battery.
  • A
    Alicia JosephSep 1, 2025
    What to do if the internal relay of my Growatt Inverter switches on and off repeatedly?
    • J
      james52Sep 1, 2025
      If the internal relay of your Growatt Inverter switches on and off repeatedly when turned on, the battery might be disconnected. Check if the battery wires are properly connected.

Summary

Safety Instructions

General Safety Precautions

Outlines critical safety warnings and operating instructions for installation and use of the inverter.

Installation

Unpacking and Inspection

Instructions for checking the inverter package contents and condition upon receipt.

Basic Installation Requirements

Specifies environmental, dimensional, and mounting criteria for proper inverter installation.

Inverter Connection

Details the procedures for connecting lithium and lead-acid batteries to the inverter unit.

PV Connection

Guides the process of connecting photovoltaic (PV) modules to the inverter's input terminals.

AC Input & Output Connection

Covers the proper wiring and connection of AC power sources and loads to the inverter.

Operation

Power On;Off

Details the procedure for turning the inverter unit on and off using the front panel switch.

Specifications

Trouble Shooting

Troubleshooting Guide

Lists common problems, their possible causes, and recommended solutions for the inverter.

Manufacturer Warranty

Contact Information

Growatt SPF5000 Specifications

General IconGeneral
Output Voltage230 VAC
Battery Voltage48 VDC
Max. PV Array Power6000W
Max. Solar Charge Current100A
Max. AC Charge Current60A
Rated Power5000W
Peak Power10000W
Frequency50/60Hz
CommunicationUSB
ProtectionShort circuit, Over temperature, Reverse polarity