EasyManua.ls Logo

Growatt SPF3000 PLUS - User Manual

Growatt SPF3000 PLUS
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation
&
Operation Manual
No.28 Guangming Road, Shiyan Street, Bao'an District, Shenzhen,
Shenzhen,P.R.China
+ 86 755 2747 1942
service@ginverter.com
www.ginverter.com
T
E
W
GR - UM - 127 - A - 01
Installation Manual Of PV Off-grid Inverter
SHENZHEN GROWATT NEW ENERGY TECHNOLOGY CO.,LTD

Questions and Answers

  • V
    Veronica RojasAug 9, 2025
    Why Growatt SPF3000 PLUS Inverter has no response after power on?
    • S
      stacyhowardAug 9, 2025
      If your Growatt Inverter doesn't respond after powering it on, it could be due to: * Very low battery voltage. Check the batteries and wiring connections. * Reversed battery polarity. Re-charge the battery. * A faulty battery. Replace the battery.
  • D
    douglasbatesAug 16, 2025
    What to do if my Growatt SPF3000 PLUS Inverter shows 'UTI out end'?
    • B
      Bradley KochAug 16, 2025
      If the Growatt Inverter displays 'UTI out end', it could be due to several reasons: * The input protector may be tripped, so check the AC breaker and wiring. * The AC power quality might be insufficient; inspect the AC wires for proper thickness and length. * If using a generator, ensure it's functioning correctly and the input voltage range setting is correct. * Try setting the output source priority to 'Solar First'. * Alternatively, change the output source priority to 'Utility first'.
  • Z
    Zachary BryantAug 25, 2025
    Why does my Growatt SPF3000 PLUS Inverter shut down automatically during startup?
    • T
      thomasfarleyAug 25, 2025
      If your Growatt Inverter shuts down automatically during startup, it's likely due to: * Low battery voltage. Try re-charging the battery. * A faulty battery. In this case, replace the battery.
  • T
    Travis SanchezAug 31, 2025
    What to do if the internal relay of my Growatt Inverter switches on and off repeatedly?
    • W
      Wayne RogersAug 31, 2025
      If the internal relay of your Growatt Inverter switches on and off repeatedly when turned on, the battery might be disconnected. Check if the battery wires are properly connected.

Summary

Safety Instructions

Installation

Inverter connection

Guidelines for connecting the inverter to power sources and loads.

Lithium battery connection

Steps to connect a lithium battery to the Growatt SPF series inverter.

Lead acid battery connection

Instructions for connecting lead-acid battery packs to the inverter.

Final assembly

Steps for completing the inverter installation after wiring is done.

AC input & output connection

Procedure for wiring the AC input power source and AC output.

Operation

Specifications

Trouble Shooting

Growatt SPF3000 PLUS Specifications

General IconGeneral
Rated Power3000W
Input Voltage230 VAC
Output Voltage230 VAC
Battery Voltage24 VDC
Max PV Input Voltage145VDC
Efficiency93%
ModelSPF3000 PLUS
Max. DC Voltage145VDC
Max. Charging Current60A
Max. Efficiency93%
Input Voltage Range170-280 VAC
CoolingFan
Operating Temperature0°C - 55°C
Dimensions330 x 485 x 135 mm
Weight12 kg
Frequency50 Hz/60 Hz
Battery TypeLead-acid/Lithium
CommunicationRS232/USB
MPPT Voltage Range30-115V DC
Peak Power6000W