| Model | SPF 10000T DVM |
|---|---|
| Category | Inverter |
| Rated Power | 10000 W |
| Output Frequency | 50 Hz/60 Hz |
| Max. Output Current | 43.5A |
| Battery Voltage | 48Vdc |
| Max. Charging Current | 190 A |
| Max. Efficiency | 93% |
| Number of MPPTs | 2 |
| Max. PV Charging Current | 190 A |
| Efficiency | 93% |
| Cooling | Fan cooling |
| Max. Output Power | 10000W |
| MPPT Voltage Range | 150Vdc - 450Vdc |
| Max. DC Voltage | 450VDC |
| Output Voltage | 230 V |
| Max. Solar Input Voltage | 450VDC |
| MPPT Range | 150Vdc - 450Vdc |
| Communication | RS485 |
| Operating Temperature | -10°C to +50°C |
Contains critical safety and operating instructions that must be read and kept for future reference to prevent hazards.
Describes the multifunctional split-phase off-grid solar inverter and its integration within a hybrid power system.
Identifies and describes the components and terminals on the front and rear panels of the inverter, including switches, displays, and ports.
Details the preparation steps, including cover removal, and guidelines for safely mounting the inverter unit.
Specifies the recommended battery cable gauge and terminal size for different inverter models to ensure safe and efficient connection.
Outlines the step-by-step procedure for connecting batteries and highlights critical safety precautions for the process.
Highlights critical safety precautions for AC wiring, including polarity and appliance restart delay considerations.
Guides the selection of PV modules based on voltage parameters (Voc) and inverter specifications for optimal performance.
Details how to turn the inverter on/off and provides an overview of the operation and display panel layout.
Details how to configure the output source priority (Solar, Utility, SBU) for powering loads.
Explains how to set the maximum total charging current for solar and utility chargers.
Lists fault codes, their corresponding events, and the icons displayed on the inverter for troubleshooting.
Provides a list of warning codes, events, audible alarms, and flashing icons for system status indication.
Addresses issues where the unit shuts down during startup or shows no response after power on, with possible causes and solutions.
Provides troubleshooting steps for continuous buzzer beeps and a solid red LED, referencing specific fault codes.
Lists specifications for the inverter's output (power, voltage, frequency) and solar charger (current, voltage, power).
Details DC input parameters (voltage cut-off, warning levels) and AC input specifications (voltage range, frequency).
Covers bypass and protection specifications (transfer time, overload, short circuit) and mechanical details (dimensions, weight).