EasyManua.ls Logo

Growatt SPH6000 User Manual

Growatt SPH6000
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Manual of SPH series

Other manuals for Growatt SPH6000

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH6000 and is the answer not in the manual?

Growatt SPH6000 Specifications

General IconGeneral
ModelSPH6000
CategoryInverter
Rated Power6000 W
Max. DC Voltage550 V
Max. Output Current27.3 A
Start Voltage150 V
Nominal DC Voltage360V
Number of DC Inputs2
Number of MPP Trackers2
Nominal AC Power6000 W
Max. AC Power6600 W
Nominal Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Max. Output Power6600 W
Output Voltage230V
Output Frequency50/60 Hz
Nominal AC Voltage230V
AC Voltage Range180V-280V
Power Factor0.8 leading - 0.8 lagging
CommunicationRS485
Cooling MethodNatural Convection

Summary

Safety

Safety Instructions

Provides crucial safety guidelines for installation and operation.

Safety Measures

Details safety measures for installation and operation.

Installation

Basic Installation Requirements

Specifies essential requirements for SPH installation location and conditions.

Installation Tools & LAN

Required Tools

Lists necessary tools for installation, including RJ45 terminal setup.

Installation Instructions

SPH Mounting

Wall Mounting Procedure

Details the step-by-step process for mounting the SPH unit on the wall.

System Connection Modes

DC Connection Conditions

Specifies requirements for PV module connection and DC input limits.

PV Array Connection

Provides safety warnings and instructions for connecting the PV array.

AC and Off-Grid Terminals

AC Grid & EPS Output Connection

Explains how to connect the AC grid output and EPS output terminals.

Battery Connection

Battery Terminal Wiring

Step-by-step guide for connecting the battery cables to the inverter.

CT Terminal Connection

CT Cable Installation

Instructions for connecting the Current Transformer (CT) terminal.

Meter Terminal Connection

Lithium Battery Communication

Lithium Battery RS485 Comm.

Grounding Connection

Grounding Requirements

Details the grounding point and minimum wire diameter for SPH.

Commissioning

Work Mode Setup

Communication

System Start-up and Shut Down

Fault Removal

System Fault List

Lists error messages and their corresponding suggestions for resolution.

Product Specifications