Error 405 Relay fault
Restart inverter.
Please contact Growatt service center if restart can’t
solve the problem.
Error 123
Autotest failed
(only in Italy)
Restart inverter.
Please contact Growatt service center if restart can’t
solve the problem.
PV Isolation Low PV isolation too low
Check the connection of PV panels and inverter is
good or not.
Check the PE of inverter is good or not.
OP Short Fault! EPS Output Short Fault
Check the load of EPS.
Check the output of EPS. Especial not connect to grid
NTC Open Internal temperature failed Please contact Growatt service center
Error 406
Model set up not meet with
certification
Please check model set or check the DIP setting
Residual I High Leakage current too high
Check the cable of inverter.
Restart inverter.
Please contact Growatt service center if restart can’t
solve the problem
Error 408 Temperature over range
Please check the temperature is in the range of
specification or not.
PV Voltage High PV voltage higher than datasheet
Please check the voltage of PV input is in the range
of specification or not.
10 Manufacturer Warranty
This certificate represents a 5 year warranty for the Growatt products listed below. Possession of this
certificate validates a standard factory warranty of 5 years from the date of purchase.
Warranted products
This warranty is applicable solely to the following products:
Growatt SPH3000.
Growatt SPH3600.
Growatt SPH4000.
Growatt SPH4600.
Growatt SPH5000.
Growatt SPH6000.
SPH 3000TL BL-UP
SPH 3600TL BL-UP
SPH 4000TL BL-UP
SPH 4600TL BL-UP
SPH 5000TL BL-UP
SPH 6000TL BL-UP
Limited Product Warranty
(Applicable under normal application, installation, use and service conditions) Growatt warrants the above

Other manuals for Growatt SPH6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH6000 and is the answer not in the manual?

Growatt SPH6000 Specifications

General IconGeneral
ModelSPH6000
CategoryInverter
Rated Power6000 W
Max. DC Voltage550 V
Max. Output Current27.3 A
Start Voltage150 V
Nominal DC Voltage360V
Number of DC Inputs2
Number of MPP Trackers2
Nominal AC Power6000 W
Max. AC Power6600 W
Nominal Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Max. Output Power6600 W
Output Voltage230V
Output Frequency50/60 Hz
Nominal AC Voltage230V
AC Voltage Range180V-280V
Power Factor0.8 leading - 0.8 lagging
CommunicationRS485