Growatt SPH3600 - User Manual

Growatt SPH3600
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation
&
Operation Manual
Shenzhen Growatt New Energy Technology CO.,LTD
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
+86 0755 2747 1942
www.ginverter.com
T
E service@ginverter.com
W
GR - UM - 139 - A - 00
Installation Manual of SPH series

Other manuals for Growatt SPH3600

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH3600 and is the answer not in the manual?

Growatt SPH3600 Specifications

General IconGeneral
ModelSPH3600
TypeHybrid Inverter
Rated Power3600 W
Max PV Input Voltage550 V
Number of MPPTs2
Max Input Current per MPPT11 A
Nominal DC Voltage360 V
Nominal AC Power3600 W
Max AC Current16 A
Nominal AC Voltage230 V
AC Voltage Range180-280V
Nominal Grid Frequency50/60 Hz
THDi<3%
Max Efficiency97.5%
DC SwitchYes
Protection DegreeIP65
Battery Voltage Range42 V - 59 V
Communication InterfacesRS485, WiFi
Max AC Power3600W
Euro Efficiency97.0%
Operating Temperature Range-25°C to +60°C
CoolingNatural Convection

Summary

Brief Introduction

1.4 Safety Instructions

Lists crucial safety guidelines to follow during installation and operation.

Safety

2.2 Safety Measure

Details essential safety measures to prevent electrical shock and burns.

2.3 Symbols introduction on the SPH inverter

Explains the meaning of warning symbols and indicators on the SPH inverter.

Installation

5.1 Basic installation requirements

Lists the fundamental prerequisites for installing the SPH inverter.

5.3 Installation Instructions

Provides step-by-step instructions for installing the SPH inverter.

5.3.2 Installation of SPH

Detailed steps for mounting and installing the SPH inverter on a wall.

5.4 SPH System Connection Mode

Explains the various methods for connecting the SPH system components.

5.4.1 Connection of PV terminal

Step-by-step guide for connecting the PV input terminals using MC4 connectors.

5.4.2 Connection of AC terminal and off grid terminal

Instructions for connecting AC output and off-grid terminals.

5.4.3 Connection of battery terminal

Details the procedure for connecting the battery terminals to the inverter.

5.4.9 Grounding connection

Details the grounding connection requirements for the SPH inverter and PV array.

Commissioning

6.1 Commissioning of SPH

Outlines the procedure for commissioning the SPH inverter after installation.

6.2.2 Fault mode

Describes how the system handles and displays fault information.

6.2.6 shutdown mode

Provides the procedure for safely shutting down the SPH inverter.

6.4.4 Work Mode Setup

Guides users on how to set up and configure the inverter's work modes.

Start-up and shut down SP system

7.1 Start-up the SPH system

Provides steps for safely starting up the SPH inverter.

Fault removal

9.1 System fault information list and troubleshooting suggestions

Lists common error messages and their corresponding troubleshooting steps.

Related product manuals