Model | SPH5000 |
---|---|
Type | Hybrid Inverter |
Rated Power | 5000 W |
Max. DC Voltage | 550 V |
Max. Output Current | 22 A |
Weight | 25 kg |
Max. DC Power | 6000 W |
Start Voltage | 150 V |
Nominal DC Voltage | 360 V |
Number of MPP Trackers | 2 |
AC Nominal Power | 5000 W |
Max. AC Apparent Power | 5000 VA |
AC Nominal Voltage | 230 V |
AC Voltage Range | 180-280V |
Nominal Grid Frequency | 50/60Hz |
Total Harmonic Distortion (THDi) | <3% |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
DC Injection Current | <0.5% In |
Switching Time | <10 ms |
Max. Charge/Discharge Power | 5000 W |
Max. Charge/Discharge Current | 100 A |
Protection degree | IP65 |
Max. PV Input Voltage | 550 V |
Cooling Method | Natural Convection |
Communication with BMS | CAN |
Operating Temperature Range | -25°C to 60°C |
MPPT Voltage Range | 120 V - 550 V |
Provides essential safety guidelines for installation and operation of the SPH inverter.
Outlines critical safety warnings regarding high voltage, hot surfaces, radiation, and grounding.
Details essential requirements for installing the SPH inverter, including location, material, and environmental factors.
Provides instructions for installing the SPH inverter, including projection, drilling, and mounting steps.
Detailed steps for physically installing the SPH inverter on a wall.
Explains how to connect the SPH system, focusing on PV terminal connection.
Details the steps for connecting PV panels using MC4 PV terminals.
Guides on connecting AC output and off-grid terminals, including wire suggestions and steps.
Provides steps for connecting the battery terminals to the SPH inverter.
Covers grounding connection for the SPH, including PV array and DC grounding.
Outlines the steps for electrifying and commissioning the SPH inverter after installation.
Describes the different operating modes of the SPH inverter, such as Normal, Backup, and Grid-first.
Explains the Normal mode, including Online and Backup modes, and priority settings for load and battery.
Details the SPH's fault mode, how system faults are monitored, and where to find fault information.
Provides steps for safely shutting down the SPH inverter by disconnecting all energy sources.
Lists common system fault messages and provides troubleshooting suggestions for the SPH inverter.
Provides detailed technical specifications for the Growatt SPH series energy storage machines.