very seldom equal to the direct product of the volts and amperes. In order to find the power of a
single phase ac circuit the product of volts and amperes must be multiplied by the power factor.
PV
Abbreviation for photovoltaic
BAT
BAT is an acronym for lithium or lead acid battery
Charging
An SPH hybrid inverter charger uses PV energy or grid energy to charge a battery
Discharging
It means that the SPH hybrid inverter supplies the battery energy to the load
wireless communication
The external wireless communication technology is a radio technology that allows the inverter and
other communication products to communicate with each other. The external wireless
communication does not require line of sight between the devices and it is selective purchasing.
1.4 Product Description
SPH Series is used to store energy generated by the photovoltaic cell panels or energy from grid if it is
allowed in the battery, also energy can be sent to power grid through SPH for self consumption or when Grid
power is lost, SPH can be used as backup power.
SPH series has six kinds of type:
Growatt SPH3000.
Growatt SPH3600.
Growatt SPH4000.
Growatt SPH4600.
Growatt SPH5000.
Growatt SPH6000.
SPH 3000TL BL-UP
SPH 3600 TL BL-UP
SPH 4000TL BL-UP
SPH 4600TL BL-UP
SPH 5000TL BL-UP
SPH 6000TL BL-UP
Note: We describe this series as “SPH” as below.
Note:
In different country, we provide different power. Such as in Germany, we can provide SPH 3000~SPH
4600TL BL-UP& Growatt SPH3000~ Growatt SPH4600, but we don’t provide SPH 5000TL BL-UP (Growatt
SPH5000 )and SPH 6000TL BL-UP(Growatt SPH6000).
Overview:

Other manuals for Growatt SPH6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH6000 and is the answer not in the manual?

Growatt SPH6000 Specifications

General IconGeneral
ModelSPH6000
CategoryInverter
Rated Power6000 W
Max. DC Voltage550 V
Max. Output Current27.3 A
Start Voltage150 V
Nominal DC Voltage360V
Number of DC Inputs2
Number of MPP Trackers2
Nominal AC Power6000 W
Max. AC Power6600 W
Nominal Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Max. Output Power6600 W
Output Voltage230V
Output Frequency50/60 Hz
Nominal AC Voltage230V
AC Voltage Range180V-280V
Power Factor0.8 leading - 0.8 lagging
CommunicationRS485
Cooling MethodNatural Convection