Connect cables to relative bolts shown in figure above , specifications of cables
must meet the requirements shown in the table above;
Cable requirements:
Model
_(mm)
Area(mm²)
AWG no.
10000UE
12000UE
18000UE
20000UE
_2.05
_2.05
_2.59
_2.59
3.332
3.332
5.260
5.260
12
12
10
10
The interface of the connector:
Assemble the connector as figures shown below;
1
2
3
N
E
1
2
Notes
AC output, please make sure that the AC breaker has been turned off (open).
: The connector must be screwed firmly. Before you operating and wiring the
4.2 Wiring DC Input
The open circuit voltage of each string should never exceed 1000Vac, while the
length must be less than 30m;
The diagram drawing of DC side is shown as below, notice that the connectors
are in paired (male and female connectors). The connectors for PV arrays and
inverters are MC (multi-connector) connectors;
Connect the positive and negative terminals from the PV panels to positive and
negative terminals on the PV inverter. The maximum string currents are varying
from different inverter types
3
4
5
Notes
package.