Questions and Answers

  • E
    Edward AlvarezSep 10, 2025
    How do I fix 'Communication fault M3 didn't receive SP-CT data' on my Growatt MID 10KTL3-X?
    • M
      Matthew RaySep 10, 2025
      If your Growatt Inverter displays 'Communication fault M3 didn't receive SP-CT data', check the communication wire. If the error message persists, it is recommended to contact the manufacturer.
  • J
    Joseph MontesAug 22, 2025
    What to do if my Growatt Inverter displays 'No Utility'?
    • A
      Ann BennettAug 22, 2025
      If your Growatt Inverter shows 'No Utility', first confirm if the grid is lost or not. If the error message persists, it is recommended to contact the manufacturer.
  • K
    Karen McmillanAug 25, 2025
    How to troubleshoot a 'No AC Connection' error on a Growatt Inverter?
    • F
      flynnsarahAug 25, 2025
      If your Growatt Inverter shows 'No AC Connection', first shutdown the system and check the AC wiring. If the error message persists, it is recommended to contact the manufacturer.
  • C
    christianwilsonAug 26, 2025
    What causes 'AC V Outrange' on a Growatt MID 10KTL3-X and how do I fix it?
    • B
      brandonortegaAug 26, 2025
      If your Growatt Inverter indicates 'AC V Outrange', begin by checking the grid voltage. If the error message continues to appear even when the grid voltage is within the tolerable range, contact the manufacturer.
  • V
    Valerie LyonsAug 28, 2025
    What should I do if my Growatt MID 10KTL3-X Inverter shows a 'Grid frequency outrange' error?
    • D
      Dr. Gregg GarciaAug 28, 2025
      If your Growatt Inverter displays 'Grid frequency outrange', check if the frequency is within the specified range. If the error message persists, it is recommended to contact the manufacturer.
  • K
    Kevin MarshAug 29, 2025
    How to fix a 'PE abnormal' error on a Growatt Inverter?
    • S
      Sandra WaltonAug 29, 2025
      If your Growatt Inverter displays 'PE abnormal', check the PE line to ensure it is making good contact. If the error message persists, contact the manufacturer.
  • N
    Nicholas VasquezSep 18, 2025
    What happens if the DC input voltage exceeds the maximum on a Growatt MID 10KTL3-X Inverter?
    • P
      Patricia TuckerSep 18, 2025
      If your Growatt Inverter indicates that 'The DC input voltage is exceeding the maximum tolerable value', immediately disconnect the DC switch and check the voltage. If the fault code persists after the normal voltage is restored, contact the manufacturer.
  • M
    Mark MooreSep 12, 2025
    How to fix 'String PID quick connect terminal detection error' on Growatt Inverter?
    • M
      Mark MorrisSep 12, 2025
      If your Growatt Inverter displays 'String PID quick connect terminal detection error', after shutdown, check the string terminal wiring. If the error message persists, it is recommended to contact the manufacturer.
  • E
    Elizabeth PetersonSep 8, 2025
    What to do if Growatt Inverter reports 'Fan function abnormal'?
    • J
      Janet HuertaSep 8, 2025
      If your Growatt Inverter displays 'Fan function abnormal', after shutdown, check the fan connection and replace the fan. If the error message persists, it is recommended to contact the manufacturer.
  • A
    Angela PerezSep 5, 2025
    How to troubleshoot a 'Communication fault' on a Growatt MID 10KTL3-X?
    • A
      Andrew JimenezSep 5, 2025
      If your Growatt Inverter displays 'Communication fault', check the communication wire. If the error message persists, it is recommended to contact the manufacturer.

Summary

2 Introduction

2.4 Safety instructions

Outlines critical safety precautions and warnings for inverter installation and operation.

3 Product description

5 Installation

5.1 Basic installation requirements

Lists fundamental requirements for safe and effective inverter mounting and placement.

5.2 Mounting wall mount

Provides instructions and specifications for securely mounting the inverter on a wall.

5.3 Installing the inverter

Details the steps for physically hanging and securing the inverter onto its mount.

6 Inverter Wiring

6.1 Safety

Highlights critical safety warnings related to electrical connections for the inverter.

6.2 AC side wiring

Guides on making correct AC electrical connections to the inverter, including breaker requirements.

6.3 DC side wiring

Explains how to safely connect DC input from PV modules, including voltage and current limits.

7 Debugging

8 Operating Mode

9 OLED Display and Touch Buttons

10 Communication and Monitoring

11 Start and Shut Down the Inverter

13 Troubleshooting

13.1 Error message

Explains how error messages are displayed and what information to provide for support.

13.2 System error

Lists warning and error codes with fault descriptions and suggested corrective actions.

14 Specification

Growatt MID 10KTL3-X Specifications

General IconGeneral
ModelMID 10KTL3-X
Max. DC Input Voltage1100 V
Nominal DC Voltage600 V
Number of MPP Trackers2
Rated Output Current14.5 A
AC Grid Frequency50 / 60 Hz
Total Harmonic Distortion (THD)< 3%
DC SwitchYes
TopologyTransformerless
Protection DegreeIP65
Max. DC Power15 kW
MPPT Voltage Range160 - 1000 V
Rated Power10 kW
Max. AC Power11000 W
Nominal AC Voltage230 V
AC Output Frequency50/60 Hz
Power Factor0.8 leading - 0.8 lagging
Protection ClassClass I
Overvoltage CategoryII
Operating Temperature Range-25°C to 60°C