EasyManua.ls Logo

Growatt MID 15KTL3-X - User Manual

Growatt MID 15KTL3-X
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Shenzhen Growatt New Energy Technology CO.,LTD
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
+86 755 2747 1942
www.ginverter.comwww.ginverter.com
T
E
W
service@ginverter.comservice@ginverter.com
+86 755 2747 1942
Download
Manual
Growatt New Energy
Installation
Operation Manual
&
GR-UM-160-A-00GR-UM-160-A-00

Questions and Answers

  • J
    Joseph AdamsSep 10, 2025
    How do I fix 'Communication fault M3 didn't receive SP-CT data' on my Growatt MID 15KTL3-X Inverter?
    • I
      icookeSep 10, 2025
      If your Growatt Inverter displays 'Communication fault M3 didn't receive SP-CT data', check the communication wire. If the error message persists, it is recommended to contact the manufacturer.
  • L
    Lauren SmithAug 22, 2025
    What to do if my Growatt MID 15KTL3-X displays 'No Utility'?
    • M
      Michael AdamsAug 22, 2025
      If your Growatt Inverter shows 'No Utility', first confirm if the grid is lost or not. If the error message persists, it is recommended to contact the manufacturer.
  • T
    Terrance NielsenAug 25, 2025
    How to troubleshoot a 'No AC Connection' error on a Growatt MID 15KTL3-X?
    • J
      Jon OlsonAug 25, 2025
      If your Growatt Inverter shows 'No AC Connection', first shutdown the system and check the AC wiring. If the error message persists, it is recommended to contact the manufacturer.
  • T
    Terri AustinAug 26, 2025
    What causes 'AC V Outrange' on a Growatt MID 15KTL3-X Inverter and how do I fix it?
    • E
      Erica ThomasAug 26, 2025
      If your Growatt Inverter indicates 'AC V Outrange', begin by checking the grid voltage. If the error message continues to appear even when the grid voltage is within the tolerable range, contact the manufacturer.
  • E
    elizabeth31Aug 27, 2025
    What should I do if my Growatt Inverter shows a 'Grid frequency outrange' error?
    • F
      Frank Ramirez Jr.Aug 27, 2025
      If your Growatt Inverter displays 'Grid frequency outrange', check if the frequency is within the specified range. If the error message persists, it is recommended to contact the manufacturer.
  • J
    John Barrett MDAug 29, 2025
    How to fix a 'PE abnormal' error on a Growatt MID 15KTL3-X Inverter?
    • S
      Sharon KnappAug 29, 2025
      If your Growatt Inverter displays 'PE abnormal', check the PE line to ensure it is making good contact. If the error message persists, contact the manufacturer.
  • S
    Stephanie DixonSep 18, 2025
    What happens if the DC input voltage exceeds the maximum on a Growatt MID 15KTL3-X?
    • D
      David CarterSep 18, 2025
      If your Growatt Inverter indicates that 'The DC input voltage is exceeding the maximum tolerable value', immediately disconnect the DC switch and check the voltage. If the fault code persists after the normal voltage is restored, contact the manufacturer.
  • K
    kchurchSep 12, 2025
    How to fix 'String PID quick connect terminal detection error' on Growatt MID 15KTL3-X Inverter?
    • C
      crosbydebbieSep 12, 2025
      If your Growatt Inverter displays 'String PID quick connect terminal detection error', after shutdown, check the string terminal wiring. If the error message persists, it is recommended to contact the manufacturer.
  • F
    flemingedwardSep 8, 2025
    What to do if Growatt MID 15KTL3-X Inverter reports 'Fan function abnormal'?
    • J
      jacksonkeithSep 8, 2025
      If your Growatt Inverter displays 'Fan function abnormal', after shutdown, check the fan connection and replace the fan. If the error message persists, it is recommended to contact the manufacturer.
  • M
    Marc OconnellSep 5, 2025
    How to troubleshoot a 'Communication fault' on a Growatt MID 15KTL3-X?
    • T
      tabitharichardsSep 5, 2025
      If your Growatt Inverter displays 'Communication fault', check the communication wire. If the error message persists, it is recommended to contact the manufacturer.

Summary

Notes on this Manual

1.1 Validity

Manual scope and product models covered.

1.2 Target Group

Identifies intended audience for the manual.

1.3 Additional Information

Location for further documentation and liability disclaimer.

Introduction to Growatt Inverters

2.1 Foreword

Introduces the manual's purpose for Growatt PV inverters.

2.2 Applicable Personnel

Specifies qualified personnel for installation and troubleshooting.

2.3 Product Overview and Features

Describes the function and connectivity of Growatt PV inverters.

2.3.2 Product Features

Lists the key characteristics and specifications of the inverter.

2.4 Safety Instructions

Provides critical safety guidelines and warnings for installation and operation.

2.4.1 Sign Convention

Explains the meaning of safety symbols used in the manual.

Product Description and Specifications

3.1 Appearance Overview

Details the physical components and ports of the inverter.

3.2 Dimensions

Provides physical dimensions and weight specifications of the inverter.

3.3 Storage Environment

Specifies optimal conditions for storing the inverter.

Unpacking and Installation Guide

4 Unpacking and Inspection

Procedure for checking the inverter and its accessories after unpacking.

5.1 Basic Installation Requirements

Lists essential criteria for inverter installation location and environment.

5.2 Mounting Wall Mount

Details the procedure for mounting the inverter on a wall.

5.3 Installing the Inverter

Step-by-step guide for physically attaching the inverter to the wall mount.

Inverter Wiring Procedures

6.1 Safety

Critical safety precautions before and during inverter wiring.

6.2 AC Side Wiring

Instructions for connecting the AC power cables to the inverter.

6.3 DC Side Wiring

Detailed steps for connecting the DC input from PV modules to the inverter.

6.4 Connecting Signal Line

Guide for establishing communication connections via the signal port.

Operation and Maintenance

7 Debugging Process

Step-by-step procedure for debugging the inverter and verifying its operation.

8.1 Normal Mode

Describes the inverter's typical operational state and conditions.

8.2 Failure Mode

Explains how the inverter indicates and behaves during system failures.

8.3 Shutdown Mode

Details the inverter's behavior when stopping operation due to low light or no sunlight.

OLED Display and Touch Controls

9.1 Boot Display

Information displayed on the OLED screen upon inverter startup.

9.1.2 Parameter Setting (General Settings)

Guide to configuring general inverter parameters via the touch interface.

9.2 OLED Display Wake Up

How to reactivate the OLED display after it automatically turns off.

9.3 Touch Operation

Explains the functions triggered by different touch gestures on the panel.

Communication and Monitoring Features

10.1 RS485

Details the RS485 communication ports and pin functions for monitoring.

10.2 DRM

Explains the DRM communication function and its pin assignments.

10.3 USB-A

Describes the use of the USB-A port for monitoring modules or firmware updates.

Inverter Start-up and Shutdown

11.1 Start the Inverter

Steps to safely power on and start the inverter.

11.2 Shut Down the Inverter

Procedures for safely powering off the inverter.

Fan Maintenance

Fan Cleaning and Replacement Steps

Detailed steps for cleaning or replacing the inverter's cooling fan.

Troubleshooting Common Issues

13.1 Error Message Information

Information needed when contacting support for error messages.

13.2 Warning and Error Codes

Lists warning and error codes, fault descriptions, and suggested actions.

Technical Specifications

14.1 Parameter

Technical specifications for various inverter models.

14.2 Torque

Specifies torque values for different screws and terminals.

14.3 Annex

Lists available product attachments and their brief descriptions.

Contact Us for Support

Contact Information

Growatt service hotline and required information for technical support.

Growatt MID 15KTL3-X Specifications

General IconGeneral
ModelMID 15KTL3-X
TypeString Inverter
Max. DC Input Power22.5 kW
Max DC Input Voltage1100 V
Start Voltage200 V
Nominal DC Voltage600 V
Number of MPPT2
Nominal AC Power15 kW
THDi< 3%
THD< 3%
DC SwitchYes
Operating Temperature Range-25 °C to +60 °C
Ingress ProtectionIP65
TopologyTransformerless
Protection LevelIP65
Rated Power15000W
Input Voltage Range200 V - 1000 V
Max. AC Apparent Power16500VA
Rated Output Power15000W
AC Voltage Range180 V - 280 V
Nominal Grid Frequency50 Hz / 60 Hz
AC Frequency Range45 Hz - 55 Hz / 55 Hz - 65 Hz
Protection ClassClass I
CommunicationRS485
Cooling MethodNatural Cooling