10 Decommissioning10 Decommissioning
10.1 Dismantling the Inverter
1. Disconnect the inverter as described in section 7.
2. Remove all connection cables from the inverter.
CAUTION
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has
cooled down.
3. Screw off all projecting cable glands.
4. Lift the inverter off the bracket and unscrew the bracket screws.
10.2 Packing the Inverter10.2 Packing the Inverter
If possible, always pack the inverter in its original carton and secure it with tension
belts. If it is no longer available, you can also use an equivalent carton. The box must
be capable of being closed completely and made to support both the weight and the
size of the inverter.
10.3 Disposing of the Inverter10.3 Disposing of the Inverter
Do not dispose of faulty inverters or accessories together
with household waste. Please accordance with the disposal
regulations for electronic waste which apply at the
installation site at that time. Ensure that the old unit and,
where applicable, any accessories are disposed of in a
proper manner.
11Specification 11Specification
11.1 Specification of Growatt UE
Model
Growatt 4000UE Growatt 5000UE Growatt 6000UE
Specification
Input data
Max. DC power
4200W 5200W 6300W
Max. DC voltage
800V 800V 800V
Start Voltage
150V 150V 150V
PV voltage range
140V-800V 140V-800V 140V-800V
MPP voltage range/
nominal voltage
200V-800V/580V 200V-800V/580V 200V-800V/580V
Max. input current
9A/9A 9A/9A 10A/10A
Number of independent
MPP trackers/strings per
MPP tracker
2/1 2/12/1
Full load voltage
range
250V-750V 300V-750V 350V-750V