Output (AC)
Max. output current 6.4A
7.9A
9.3A
AC nominal voltage;
range
3/N/PE, 230V/400V
185~260V
3/N/PE, 230V/400V
185~260V
3/N/PE, 230V/400V
185~260V
AC grid frequency;
range
50/60Hz
44-55Hz/54-65Hz
50/60Hz
44-55Hz/54-65Hz
50/60Hz
44-55Hz/54-65Hz
Power factor
0.9leading -
0.9laging
0.9leading -
0.9laging
0.9leading -
0.9laging
THDi <3% <3% <3%
AC grid connection type Three phase Three phase Three phase
Efficiency
Max efficiency
97.8% 97.8% 97.8%
Euro-eta
96.5% 96.6% 96.8%
MPPT efficiency
99.5% 99.5% 99.5%
Protection devices
DC reverse polarity protection
yes yes yes
DC switch for each MPPT
yes yes yes
Output AC overcurrent protection
yes yes yes
Output AC overvoltage
Protection - Varistor
yes yes yes
Ground fault monitoring
yes yes yes
Grid monitoring
yes yes yes
Integrated all-pole sensitive
leakage current monitoring unit
yes yes yes
General Data
Dimensions(W/H/D)
in mm
433/620/194 mm
17.0/24.4/7.6 inch
433/620/194 mm
17.0/24.4/7.6 inch
433/620/194 mm
17.0/24.4/7.6 inch
Weight 30kg/66.2lb 32.5kg/71.7lb 32.5kg/71.7lb
Operating
temperature range
–25 °C ... +60 °C
(–13 °F ... +140 °F)
With derating above
45 °C(113 °F)
–25 °C ... +60 °C
(–13 °F ... +140 °F)
With derating above
45 °C(113 °F)
–25 °C ... +60 °C
(–13 °F ... +140 °F)
With derating above
45 °C(113 °F)
Noise emission (typical) ≤ 35 dB(A) ≤ 35 dB(A) ≤ 35 dB(A)
Power factor at rated power 1
1
1
Nominal AC power PF 0 95(=. )
3800W 4750W
5700W
Max. AC apparent power
4000VA 5000VA 6000VA
Max AC power PF 1.(=)
4000W 5000W 6000W
65