1. After shutdown,Check the panel is
normal.
2. If error message still exists, contact
manufacturer.
String PID quick connect
terminal detection error
1. After shutdown,Check the string terminal
wiring.
2. If the error message still exists, contact
the manufacturer.
1. After shutdown,Check the DC SPD.
2. If error message still exists,contact
manufacturer.
1: Check the PV1 or PV2 wiring is short-
circuited
2: If error message still exists,contact
manufacturer.
Dryconnect function
abnormal
1. After shutdown,Check the dry Dryconnect
wiring.
2. If the error message still exists, contact
manufacturer.
1. Restart inverter.
2. If error message still exists,contact
manufacturer.
1. After shutdown,Check the AC SPD.
2. If error message still exists,contact
manufacturer.
U disk over-current
protection
1: unplug the U disk
2: Re-access U disk after shutdown
3. If the error message still exists, contact
manufacturer.
1. After shutdown,Check fuse.
2. If error message still exists, contact
manufacturer.
The DC input voltage is
exceeding the maximum
tolerable value.
1. Immediately disconnect the DC switch and
check the voltage
2. If the fault code still exists after the
normal voltage is restored, contact
manufacturer
1: Check PV input terminals
2: If error message still exists,contact
manufacturer.
13.2 Syetem error
13.2.1 Warning code
1. Please confirm grid is lost or not.
2. If error message still exists,contact
manufacturer.
1. Check the AC voltage is in the range
of standard voltage in specification.
2. If error message still exists,contact
manufacturer.
1. Check the frequency is in the range
of specification or not.
2. If error message still exists,contact
manufacturer.
1. Please reduce the load of EPS output.
2. If error message still exists,contact
manufacturer.
1: Check if AC current sensor is connected
well.
2: If error message still exists,contact
manufacturer.
SP-CT L N line reversed
or Ground fail
1: Check the L line and N line of SP-CT is
reversed or not.
2: If error message still exists,contact
manufacturer.
Communication fault,
M3 didn't receive SP-CT
data
1: Check communication wire
2: If error message still exists,contact
manufacturer.
1: Check communication wire
2: If error message still exists,contact
manufacturer.
1.After shutdown,Check the fan connection.
2. replace the fan.
3. If the error message still exists, contact
manufacturer.
1: Check if the meter is on
2: Check the machine and the meter
connection is normal .
Optimizer and inverter
communication is
abnorma
1. Check if the optimizer is on.
2. Check whether the connection between
the optimizer and the inverter is normal.
String communication
abnormal
1. After shutdown,Check the string panel
wiring.
2. If the error message still exists, contact
manufacturer .