8 Start-Up and shut down the inverter
8.1 Start-Up the inverter
1. Connect the AC breaker of the inverter.
2. Turn on the dc switch, and the inverter will start automatically when the input
voltage is higher than 70 V.
8.2 Turn-off the Inverter
DANGER
Do not disconnect the DC connectors under load.
Turn-off the inverter step:
1. Disconect the line circuit breaker from single-phases grid and prevent it from
being reactivated.
2. Turn off the dc switch.
3. Check the inverter operating status.
4. Waiting until LED, OLED have go out, the inverter is shut down.
9 Maintenance and Cleaning
9.1 Checking Heat Dissipation
If the inverter regularly reduces its output power due to high temperature,
please improve the heat dissipation condition. Maybe you need to clean the
heat sink.