45
46
Max output fault current
Backfeed current
Max output overload
protection
P o w e r f a c t o r ( @ n o m i n a l
power)
53A
25A
0A
>0.99
32A
32A
Adjustable power factor
AC grid connection type
AC overvoltage category
0.8leading… 0.8lagging
THDi
<3%
Efficiency
Single phase
Category III
Max. efficiency
Euro-eta
98.4%98.4%98.4%
97.5%97.5%97.5%
Protection devices
DC reverse-polarity protection
Anti-islanding protection
DC switch
DC Surge protection
Insulation resistance
monitoring
AC surge protection
AC short-circuit protection
Ground fault monitoring
Grid monitoring
Residual-current monitoring
unit
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Type III
Type III
General data
Dimensions (W / H / D) in mm
Weight
Operating temperature range
375*350*160
10.8 kg
–25 °C ... +60 °C
Noise emission (typical)
Altitude
Internal consumption at night
Topology
Cooling
Protection degree
Relative humidity
DC connection
AC connection
Interfaces
≤ 25 dB(A)
4000m
<1W
transformerless
Natural convection
IP65
0~100%
VP-D4/MC4(Optional)
AC connector
Display
RS485/USB
WIFI/GPRS/4G/LAN/ RF
Warranty:5/10 years
OLED+LED
Integrated
Optional
Yes/ Optional
14.2 DC &AC connector info
14.3 Torque
DC connector
VP-D4/ MC4(opt)
AC connector
M-S30_SD03_S10 001U-A
VPAC06EP-3S(SC)5
VPAC06EW-3P(SC)
Enclosure lid screws
AC terminal
Signal terminal
Safety screw
Additional ground screws
12kg.cm
6kg.cm
4kg.cm
12kg.cm
12kg.cm
* The AC Voltage Range may vary depending on specific country grid standard.
All specifications are subject to change without notice.