44
Adjustable power factor
AC grid connection type
AC overvoltage category
0.8leading… 0.8lagging
THDi
<3%
Efficiency
Single phase
Category III
Max. efficiency
Euro-eta
98.2% 98.2% 98.2% 98.4%
97.1% 97.1% 97.2% 97.2%
Protection devices
DC reverse-polarity protection
Anti-islanding protection
DC switch
DC Surge protection
Insulation resistance
monitoring
AC surge protection
AC short-circuit protection
Ground fault monitoring
Grid monitoring
Residual-current monitoring
unit
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Type III
Type III
General data
Dimensions (W / H / D) in mm
Weight
Operating temperature range
Noise emission (typical)
Altitude
Internal consumption at night
Topology
Cooling
Protection degree
Relative humidity
DC connection
AC connection
Interfaces
375*350*160
10.8 kg
–25 °C ... +60 °C
≤ 25 dB(A)
4000m
<1W
transformerless
Natural convection
IP65
0~100%
VP-D4/MC4(Optional)
AC connector
Display
RS485/USB
WIFI/GPRS/4G/LAN/ RF
Warranty:5/10 years
OLED+LED
Integrated
Optional
Yes/ Optional
Model
Specifications
4600TL-X 5000TL-X 6000TL-X
Input data(DC)
Max. recommended PV
power(for module STC)
Max. DC voltage
Start voltage
Nominal voltage
MPP voltage range
MPP voltage range at Full
Power
No. of MPP trackers
No. of PV strings per
MPP trackers
Max. input current per
MPP trackers
Max. short-circuit current
per MPP trackers
DC overvoltage category
Output data(AC)
AC nominal power
Max. AC apparent power
Nominal AC voltage/range*
AC grid frequency/range
Max. output current
Inrush current
6400W
550V
100V
360V
7000W 8100W
80-550
80-550
80-550
185V-500V
200V-500V 235V-500V
2
1
12.5A
16A
Category II
4.6kW
5kW
6kW
4.6kVA
5kVA 6kVA
230/
160~300V
50-60Hz/44-55Hz;54-65Hz
20.9A 22.7A 27.2A
<10A
230/
160~300V
230/
160~300V
43