Figure.5. Indication of setting the mode and time periods on ShinePhone
3.4. Setting through ShineBus
To set up the inverter with ShineBus, you need connect the inverter to the host computer
with the communication cable, connect the RS485 port to the BAT COM 1-2 pin of the
inverter, and connect the USB port to the host computer.
After connect the communication cable, first, click “Configuration” to use ShineBus to
read the inverter information to ensure that the inverter communicates successfully with
the host computer; After that, enter the “BDC Time Set” interface and write “start time”
and “end time” (note: The start time of the next time period must be greater than the
end time of the previous time period. After selecting the priority mode, select “Enable”
and click “Time”, when display “Set Successfully” means the setting is enable now.
To read a single time period, please select “Read” and click “Time” to successfully read
the single time period priority mode and time data.