Page #15 background imageLoading...
Page #15 background image
23
24
6.4 Connect the signal cable
The MOD series inverter has an 4-Pin or 16-Pin signal connector except Vietnam
models.The client signal line port is as follows:
1.Strip the cable 10mm through the waterproof gland, thread sleeve, and tighten the
screws.
Connect DC terminal
Cables
Cables
Positive metal terminal
Positive connector
Negative connector
Negative metal terminal
4~6mm²
4~6mm²
Fig 6.12
Fig 6.13
Fig 6.14
1
2
3
4
A just for Vietnam models
B just for Vietnam models
B
A
Fig 6.15
Fig 6.16
Fig 6.17
Fig 6.18
2. Push the threaded sleeve into the socket and tighten the waterproof gland.
3.Connect the client to the inverter plug until both are tightly locked on the inverter.
Remove the signal connector
1.Press down the fastener and pull it out of the inverter.
the inverter side
2. Insert the H-shaped tool and pull it out of the socket.
Click!
Click!
Inverter side

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MOD 10KTL3-X and is the answer not in the manual?

Growatt MOD 10KTL3-X Specifications

General IconGeneral
Max. DC Voltage1100 V
Nominal AC Power Output10000 W
Max. AC Apparent Power11000 VA
Number of MPP Trackers2
Max. Input Current per MPP Tracker16 A
Operating Temperature Range-25°C to +60°C
IP RatingIP65
Max. DC Power13000 W
Start Voltage180 V
Nominal DC Voltage600 V
Number of DC Inputs per MPPT2
Max. AC Current16 A
Nominal Grid Frequency50/60 Hz
THDI<3%
DC SwitchYes
Protection ClassClass I
TopologyTransformerless
Efficiency98.3%
Noise Level<30 dB
Cooling MethodNatural Convection
MPPT Voltage Range160 V to 1000 V
Nominal AC Voltage230/400 V
Power Factor0.8 leading ... 0.8 lagging
CommunicationRS485 / WiFi / Ethernet
AC Voltage Range310 V - 480 V