46
45
Warning
message
Description
Suggest
Warning 305
CT line reversed or
Ground fail
1.Check the L line and N line of SP-CT is reversed
or not.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 306
Communication
fault,M3 didn't
receive SP-CT data
1.Check communication wire
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 307
Communication fault
1.Check communication wire.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 400
Fan function
abnormal
1.After shutdown,Check the fan connection.
2. replace the fan.
3.If the error message still exists, contact
manufacturer.
Warning
message
Description
Suggest
Warning 202
DC SPD function
abnormal
1.After shutdown,Check the DC SPD.
2.If error message still exists,contact manufacturer.
Warning 203
PV Circuit short
1.Check the PV1 or PV2 wiring is short-circuited
2.If error message still exists,contact manufacturer.
Warning 204
Dry contact function
abnormal
1.After shutdown,Check the dry Dry contact wiring.
2 . I f t h e e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 205
PV Boost driver broken
1.Restart inverter.
2.If error message still exists,contact manufacturer.
Warning 206
AC SPD function
abnormal
1.After shutdown,Check the AC SPD.
2.If error message still exists,contact manufacturer.
Warning 207
U d i sk o ver- c u rrent
protection
1.Unplug the U disk
2.Re-access U disk after shutdown
3.If the error message still exists, contact
manufacturer.
Warning 208
DC Fuse Open
1.After shutdown,Check fuse.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 209
The DC input voltage is
exceeding the
maximum tolerable
value.
1.Immediately disconnect the DC switch and
check the voltage
2.If the fault code still exists after the normal
voltage is restored, contact manufacturer.
Warning 210
PV Reversed
1.Check PV input terminals
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 300
No Utility
1.Please confirm grid is lost or not.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 301
Grid voltage outrange
1.Check the AC voltage is in the range
of standard voltage in specification.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 302
Grid frequency
outrange
1.Check the frequency is in the range
of specification or not.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 303
EPS mode, over load
1.Please reduce the load of EPS output.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 304
CT Open or Wrong
1.Check if AC current sensor is connected well
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 401
Meter abnormal
1.Check if the meter is on
2.Check the machine and the meter connection is
normal.
Warning 402
Optimizer and inverter
c o m m u n i c a t i o n i s
abnormal
1.Check if the optimizer is on.
2.Check whether the connection between the
optimizer and the inverter is normal.
Warning 403
String communication
abnormal
1.After shutdown,Check the string panel wiring.
2.If the error message still exists, contact
manufacturer .
Warning 404
EEPROM abnormal.
1.Restart inverter.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 405
DSP and COM
f i r m w a r e v e r s i o n
unmatch
1.Check the firmware version.
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.
Warning 406
Boost module error
1.Restart inverter
2 . I f e r r o r m e s s a g e s t i l l e x i s t s , c o n t a c t
manufacturer.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MOD 10KTL3-X and is the answer not in the manual?

Growatt MOD 10KTL3-X Specifications

General IconGeneral
Max. DC Voltage1100 V
Nominal AC Power Output10000 W
Max. AC Apparent Power11000 VA
Number of MPP Trackers2
Max. Input Current per MPP Tracker16 A
Operating Temperature Range-25°C to +60°C
IP RatingIP65
Max. DC Power13000 W
Start Voltage180 V
Nominal DC Voltage600 V
Number of DC Inputs per MPPT2
Max. AC Current16 A
Nominal Grid Frequency50/60 Hz
THDI<3%
DC SwitchYes
Protection ClassClass I
TopologyTransformerless
Efficiency98.3%
Noise Level<30 dB
Cooling MethodNatural Convection
MPPT Voltage Range160 V to 1000 V
Nominal AC Voltage230/400 V
Power Factor0.8 leading ... 0.8 lagging
CommunicationRS485 / WiFi / Ethernet
AC Voltage Range310 V - 480 V

Related product manuals