47
48
Model
Specifications
MOD
9000TL3-X
MOD
10KTL3-X
MOD
11KTL3-X
MOD
12KTL3-X
MOD
13KTL3-X
MOD
15KTL3-X
Protection devices
DC reverse-polarity
protection
YES
DC switch
YES
DC Surge protection
typeII OPT
Insulation resistance
monitoring
YES
AC surge protection
typeII OPT
AC short-circuit
protection
YES
Grid monitoring
YES
Anti-islanding protection
YES
Residual-current
monitoring unit
YES
String Fuse protection
YES
String monitoring
OPT
AFCI protection
OPT
General data
Dimensions (W / H / D) in
mm
425*381* 178mm
Weight
15kg
16.5kg
Operating temperature
range
-25°C ... +60°C
(>45°CDerating)
Noise emission (typical)
 35dB(A)
Altitude
4000m
Internal consumption at
night
1W
Topology
Transformerless
Cooling
Natural heat dissipation
Electronics protection
degree
Ip66
Relative humidity
0~100%
DC connection
H4/MC4(OPT)
AC connection
Waterproof PG head+OT terminal or quick connect terminal
Interfaces
Display
OLED+LED
USB/RS485
YES
WIFI/GPRS/4G/RF/LAN
OPT
Model
Specifications
MOD
3000TL3-
X
MOD
4000TL3-
X
MOD
5000TL3-
X
MOD
6000TL3-
X
MOD
7000TL3-
X-AU
MOD
8000TL3-
X-AU
Input data(DC)
Max. recommended PV
power(for module STC)
4500W
6000W
7500W
9000W
10500W
12000W
Max. DC voltage
1100V
Start voltage
200V
Nominal voltage
580V
MPP voltage range
140-1000V
Full-load voltage range
250-800V
320-850V
No. of MPP trackers
2
No. of PV strings per MPP
trackers
1/1
1/1
1/1
1/1
1/2
1/2
Max. input current per
MPP trackers
13/13A
13/13A
13/13A
13/13A
13/26A
13/26A
Max. short-circuit current
per MPP trackers
16/16A
16/32A
Backfeed current to PV
array
0A
Output data(AC)
AC nominal power
3000W
4000W
5000W
6000W
7000W
8000W
Max. AC apparent
3000VA
4000VA
5000VA
6000VA
7000VA
8000W
Nominal AC voltage/range
230/400V
AC grid frequency/range
50/60 Hz
45~55Hz/55-65 Hz
Max. output current
4.5A
6.0A
7.6A
9.1A
10.6A
12.1A
AC inrush current
30A
Max. output fault current
24.6A
44.5A
Max. output overcurrent
Protection
24.6A
44.5A
Power factor(@nominal
power)
>0.99
Adjustable power factor
0.8Leading ...0.8Lagging
THDi
<3%
AC grid connection type
3W+PE /3W+N+PE
Efficiency
Max. efficiency
98.3%
98.6%
Euro-eta
97%
Australian models