EasyManua.ls Logo

Grundfos CR 95 - Page 20

Grundfos CR 95
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CRN 95
5
20
CR, CRN 95-155Performance curves and technical data
CRN 95
CRN 95
The maximum pump efficiency (Eta) is based on a three-stage pump.
TM06 5538 3718
0 50 100 150 200 250 300 350 400 450 500 550 600
Q [US GPM]
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
[ft]
H
0 20 40 60 80 100 120 140
Q [m³/h]
0
20
40
60
80
100
120
140
160
180
200
[m]
H
CRN 95
60 Hz
ISO 9906:2012 Grade 3B
-5-2
-5-1
-1
-1-1
-2
-2-1
-2-2
-3
-3-1
-3-2
-4
-4-2
-4-1
0 50 100 150 200 250 300 350 400 450 500 550 600
Q [US GPM]
0
5
10
15
20
[hp]
P2
0
20
40
60
80
[%]
Eff
0
4
8
12
[kW]
P2
P2
1/1
IS 3550 rpm
P2
2/3
IS 3550 rpm
Eff 3550 rpm
0 50 100 150 200 250 300 350 400 450 500 550 600
Q [US GPM]
0
40
80
120
160
[ft]
H
0
10
20
30
40
[m]
H
0
10
20
30
40
[ft]
NPSH
0
2
4
6
8
10
12
[m]
QH
1/1
IS 3550 rpm
QH
2/3
IS 3550 rpm
NPSH 3550 rpm

Other manuals for Grundfos CR 95

Related product manuals