EasyManuals Logo

Grundfos DMB Series User Manual

Grundfos DMB Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
12
Dismantle the inner parts: seat (4r), O-ring (1r), balls (3r), ball cages (2r).
Unscrew the valve cover.
3. Clean all parts. If faulty parts are detected, proceed as follows:
Replace the valve (for stainless-steel valves: inner valve parts). For contents and order numbers of the spare parts kits,
contact Grundfos Alldos.
1 Re-assemble and refit the valve.
2 Remove the deaeration cartridge (1p, 2p, 3p) under the discharge valve from the dosing head using a pair of tweezers.
Dismantle the cartridge.
Clean the cartridge. If faulty parts are detected, proceed as follows:
Replace the deaeration cartridge. For contents and order numbers of the spare parts kits, contact Grundfos Alldos.
Re-assemble the cartridge.
6. Refit all parts. See fig. 10 on page 16.
The O-rings must be correctly placed in the specified groove.
Observe the flow direction (indicatedby an arrow)!Only tighten the valve by hand.
9.4 Replacing the diaphragm
9.4.1 Switching off the pump
1 While the pump is running, set the stroke-length adjustment knob to 100 %.
2 Switch off the pump and disconnect it from the power supply.
3 Depressurise the system.
4 Take suitable steps to ensure that the returning dosing medium is safely collected.
9.4.2 Replacing the diaphragm
See fig. 11 on page 16.
1 Loosen the four screws (1q + 2q) on the dosing head (2).
2 Remove the dosing head (2).
3. Unscrew the diaphragm (Q) counter-clockwise.
For pumps without Plus
3
system: Replace the sealing diaphragm (3q), intermediate ring (4q) and support disk (5q).
4 Screw in the new diaphragm (Q).
5 Start/stop the pump briefly so that the diaphragm is set to the back dead point (end of suction stroke).
6 Replace the dosing head (2) and cross-tighten the screws (1q + 2q).
Maximum torque: DMB 1.0 - DMB 5.0: 2.1 Nm. DMB 9.0 - DMB 18: 2.5 Nm.
7 Vent and start up the dosing pump.
After initial start-up and after each time the diaphragm is changed, tighten the dosing head screws.
After approximately 6-10 operating hours or two days, cross-tighten the dosing head screws using a torque
wrench.
Maximum torque: DMB 1.0 - DMB 5.0: 2.1 Nm. DMB 9.0 - DMB 18: 2.5 Nm.