6. Start-up
If the pump is not operating satisfactorily, see section 10. Fault finding chart.
Step Action
1
Prior to start-up, retighten the dosing head screws:
Cross-tighten the screws to 5.5 Nm (+ 0.5/– 0 Nm).
2
Connect the hoses/pipes:
Connect the suction and dosing tubes/pipes to the pump.
Connect a tube to the vent valve, if required, and lead the hose to
the tank.
3
Connect the cables:
Connect the control/level cables, if any, to the pump, see
section 4.6.
4
Switch on the electricity supply:
The display is on.
The green indicator light is flashing (the pump has stopped).
Select language, if required, see section 5.20.
5
Select the operating mode (see section 5.9):
Manual.
•Pulse.
Analog.
•Timer.
•Batch.
6
Start the pump:
Start the pump by pressing the on/off button.
The green indicator light is permanently on.
7
Priming/venting:
Press the button on the pump control panel and let the pump
run without a counter pressure. Open the vent valve, if required.
When the buttons and are pressed simultaneously during
priming, the pump can be set to run for a specific number of
seconds at maximum capacity.
8
Calibration:
When the pump has been primed and is running at the right
counter pressure, calibrate the pump, see section 7.