English (GB)
30
7. Calibration
It is important that the pump is calibrated after
installation to ensure that the correct value (ml/h or
l/h) appears in the display.
The calibration can be carried out in two different
ways:
Direct calibration.
The dosed quantity of 100 strokes is measured
directly. See section 7.1.
Check calibration. See section 7.2.
Fig. 26
Operating display
without changes
Set value.
See section 7.2
Operating display Operating display
The pump
performs 100
dosing strokes