r e v i s i o n 0.0
K-Series
Instruction & Operation
Manual for KJI PUMPS
750-18, Jangnok-dong, Gwangsan-gu
Gwangju, Korea
Tel : 82-62-602-8400 (Rep.)
Web : www. kjipumps.co.kr

Questions and Answers

  • Y
    yandersonAug 9, 2025
    What to do if my Grundfos Water Pump does not start or stops immediately after starting?
    • M
      Mr. Matthew GainesAug 9, 2025
      If your Grundfos water pump fails to start or stops shortly after, several factors could be responsible. It could be due to a power failure (contact the electric power company), incorrect voltage, or a significant voltage drop. Inspect the motor and connections for motor phase malfunction. Check the electric circuit for connection faults and correct the wiring if there's a faulty control circuit connection. Replace a blown fuse with the correct type, or replace a faulty magnetic switch with the correct type. If a short circuit is present, locate and repair it. Other potential issues include foreign matter clogging the pump (remove it), a burnt-out motor (rewind it) or damaged motor bearings (replace them).
  • K
    kwilkinsAug 20, 2025
    Why does my Grundfos KJI KSE Water Pump start but stop after a short period?
    • C
      campbellgrantAug 20, 2025
      Your Grundfos Water Pump might be stopping shortly after starting because the motor protection has been activated due to prolonged dry operation. To resolve this, adjust (raise) the pump stop water level, ensuring the motor remains partially covered during operation. Alternatively, high liquid temperature may have activated the motor protector; in this case, lower the liquid temperature.
  • F
    Felicia HarperAug 28, 2025
    What to do if my Grundfos Water Pump does not pump adequate volume?
    • B
      Brian RobinsonAug 28, 2025
      If your Grundfos Water Pump isn't pumping enough water, several things could be wrong. First, check for reverse rotation and correct it. A significant voltage drop could be the cause, so contact your electric power company. Ensure you're not operating a 60Hz pump on 50Hz by checking the name plate. Also, check if the discharge head is too high or if there's large piping loss, and recalculate and adjust as necessary. Low operating water levels can cause air suction, so raise the water level or lower the pump. Inspect and repair any leaks from the discharge piping. Remove any foreign matter from clogged discharge piping or the suction inlet. If foreign matter is clogging the pump, disassemble and remove it. Lastly, a worn-out impeller can cause this issue, so replace it.

Summary

Overview

General Data

Provides general specifications and data for KJI pumps.

Information of the nameplate

Explains how to identify pumps using the nameplate and its details.

General Data

Pump code designation

Details the alphanumeric code used to designate pump models.

Maximum operating conditions

Outlines the environmental and operational limits for the pumps.

Safety Precautions

Provides essential safety guidelines and warnings for handling the pump.

General Data

Operating conditions

Specifies the acceptable operating parameters for the pumps.

Level of pumped liquid

Details the minimum and maximum liquid levels required for pump operation.

Carriage & Transport

Lifting the pump

Provides instructions and safety points for lifting the pump correctly.

Installation

Points for attention during installation

Lists important considerations and checks before and during installation.

Cable Joints

Explains how to properly extend and make waterproof cable connections.

Procedure of the Horizontal installation

Provides step-by-step instructions for carrying out horizontal installations.

Wet pit ADC installation

Describes the setup for wet pit installations using Automatic Discharge Connection.

Commissioning & Operation

Initial Examination

Outlines the checks to perform before starting the pump for the first time.

Start the pump using the following sequence of events.

Describes the sequence of events for safely starting the pump.

Control Panel wiring

Details wiring for inlet, outlet, and motor protector connections.

Maintenance, Inspection and Overhaul

Maintenance

General guidelines and points to check during routine pump maintenance.

OVERHAUL

Outlines when overhaul is needed and the general procedure.

Trouble Shooting

Grundfos KJI KSE Specifications

General IconGeneral
BrandGrundfos
ModelKJI KSE
CategoryWater Pump
LanguageEnglish