3. Select Lock GO Remote.
4. Disable the setting and press Done.
All menus in Grundfos GO Remote are unlocked.
6.22 Starting the startup wizard with the operating panel
Press and hold the OK button for 8 seconds until S-1 or S-2 starts flashing.
Related information
3.3 Startup wizard on the operating panel
7. Operating the product
7.1 Manual operation
7.1.1 Starting and stopping the pump manually with Grundfos GO Remote
1. Go to Settings > Control, pump 1 or Control, pump 2.
2. Start the pump by selecting On and pressing OK.
3. Stop the pump by selecting Off and pressing OK.
Related information
7.1.4 Choosing what the pump must do after manual start
7.1.2 Automatic operation
In automatic operating mode, the control unit starts and stops the pump based on the signals it receives from the connected level sensors and
the corresponding level settings within the control unit.
Related information
4.4 Application types
7.1.3 Starting and stopping the pump manually with the operating panel
1. To start a pump manually, press and hold the Pump button until the pump starts.
The On indicator light is lit when the pump is operating in manual mode.
2. Stop the pump by pressing the Pump button.
The Off indicator light is lit when the pump is stopped.
Related information
7.1.4 Choosing what the pump must do after manual start
7.1.4 Choosing what the pump must do after manual start
The following can be configured:
Automatic return
Here you select if the pump must automatically return to a defined operating mode when the manual start ends.
Return to
Here you select whether the pump must return to automatic operating mode or stop when the manual start ends and Automatic return
has been enabled.
Forced start time
Here you set the time period in which the pump must run in manual operating mode.
1. Go to Settings > Manual start.
2. Select Automatic return and choose one of the following options:
Disabled
Enabled.
3. Go one step back in the menu and select Return to.
4. Choose one of the following options:
Auto
Off.
5. Go one step back in the menu and select Forced start time.
6. Set the time period in which the pump must run in manual operating mode.
Related information
7.1.1 Starting and stopping the pump manually with Grundfos GO Remote
7.1.3 Starting and stopping the pump manually with the operating panel
22
English (GB)

Table of Contents

Other manuals for Grundfos LC 231

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos LC 231 and is the answer not in the manual?

Grundfos LC 231 Specifications

General IconGeneral
BrandGrundfos
ModelLC 231
CategoryWater Pump
LanguageEnglish

Related product manuals