Product Guide EZ Boost
TM
System
Main power supply to pump 1 x 200-240 V –10%/+6%, 60 Hz
1 x 110-115 V –10%/+6%, 60 Hz
Starting Soft starting.
Stopping SoftstoppingwhenstoppedbytheEZBoostcontroller
Run-uptime Maximum:2seconds.
Nolimitationtothenumberofstarts/stopsperhour.
Motorprotection Builtintothepump.
Protectionagainst:
Dryrunning
Overvoltageandundervoltage
230Vcutsoutat<150Vand>280V
115Vcutsoutat<75Vand>150V
Overload
Overtemperature
Soundpressurelevel
Thesoundpressurelevelis<74db[A]atadistanceof3feet(1meter).It is recommended by
Grundfos that the pump be installed with sound and vibration dampening equipment such as;
flexible piping adapters and anti-vibration mounting. The pump should not be mounted in or
adjacent to living quarters. The pump can also be wrapped with sound proofing insulation to
reduce noise. (See page 16, EZ Boost System Diagram.)
Resetfunction BMQEpumpscanberesetviaEZBoostcontroller.
Powerfactor PF=1.
Operationviagenerator ItisrecommendedthatthegeneratoroutputisequaltothemotorinputpowerP1[kW]plus
50%;min.P1+10%,however.
Pipeconnection 1.25”NPTinlet/1”NPTdischarge.
Strainer Holesofthestrainer:ø0.09”(2.3mm)
Marking ULListed,CE(SQEPumpwithMSE3motoronly)
Technical data - BMQE pump
20
Product Guide EZ Boost
TM
System
EZ Boost Controller
The EZ Boost controller is a control and communication
unitespeciallydevelopedfortheBMQEboosterpumpsin
constantpressureapplications.
TheEZBoostcontrollerprovides:
• FullcontroloftheBMQEpumps
• Two-waycommunicationwiththeBMQEpumps
• Possibilityofadjustingthepressure
• Alarmindication(LED)whenserviceisneeded
• The possibility of starting, stopping and resetting the
pumpsimplybymeansofapush-button
TheEZBoostcontrollercommunicateswiththepumpvia
powerlinecommunication,meaningthatno extracables
arerequiredbetweentheEZBoostcontrollerandtheBMQE
pump.
TheEZBoostcontrollerfeaturesthefollowingindications
(seedrawingbelow):
1. Flowindicator
2. Systempressuresetting
3. SystemON/OFF
4. Buttonlockindicator
5. Dry-runningindicator
6. Serviceneededincaseof:
–Nocontacttopump
–Overvoltage
–Undervoltage
–Speedreduction
–Overtemperature
–Overload
–Sensordefective
TheEZBoostcontrollerincorporatesexternalsignalinput
forpressuresensor and a pump statusrelayfor use with
devisesdependantonpumpstatus.
Voltage 1x100-240V–10%/+6%,60Hz
Power
consumption
5W
Current
consumption
Maximum130mA
Enclosureclass NEMA3R(IP55)
Ambient
temperature
Inoperation:-22to+122°F(-30to+50°C)
duringstorage:-22to+140°F(-30to+60°C)
Relative
airhumidity
95%
Pumpcable
MaximumlengthbetweenEZBoostcontrol-
lerandpump:650ft(198m).
Back-upfuse Maximum:16A
Marking ULListed,CE
Load Max.100mA
Powersupply
entry
Submersible
dropcableentry
Pressuresensor
entry
9 3/15 in. (232 mm)
4 1/2 in. (114 mm)
7 11/16 in. (195 mm)
L-DWS-PG-01 8-09.indd 20 11/12/11 12:49 AM