Sololift2 D-2
Installation and operating instructions
60 Hz
GRUNDFOS INSTRUCTIONS

Other manuals for Grundfos Sololift2 D-2

Question and Answer IconNeed help?

Do you have a question about the Grundfos Sololift2 D-2 and is the answer not in the manual?

Grundfos Sololift2 D-2 Specifications

General IconGeneral
Max Liquid Temperature50 °C
Power Supply230 V, 50 Hz
Power Consumption280 W
Insulation classF
Protection classIP44
TypeWC lifting station
Max Head6 m
Inlet SizeDN 40
Outlet SizeDN 32
InstallationFloor-standing
ApprovalsCE, VDE

Summary

General Information

Hazard Statements

Explains symbols for DANGER, WARNING, CAUTION, and SIGNAL WORD with their meaning.

Notes

Details symbols for mandatory actions, prohibitions, and tips for easier work.

Safety Instructions

Installing the product

Emphasizes professional installation and electrical safety, including RCD and main switch requirements.

Servicing the product

Highlights electric shock risks during servicing and the need for skilled personnel and power disconnection.

Fault finding the product

Warns of electric shock hazard during fault finding and the necessity of switching off the power supply.

Installing the product

Mechanical installation

Covers accessibility, frost-free placement, pipe insulation, and vibration prevention for mechanical setup.

Electrical connection

Outlines crucial electrical safety measures, including earthing, RCD, main switch, and suitability for supply.

Product introduction

Product description

Describes the D-2 as a compact automatic lifting station for grey wastewater and advises turning off water supply.

Intended use

Specifies suitability for domestic grey wastewater from showers, bidets, sinks, and requires floor fastening.

Pumped liquids

Defines acceptable liquids (grey wastewater up to 50°C, cleaning liquids pH 4-10) and prohibits harsh chemicals.

Servicing the product

Maintenance

Recommends annual checks of operation, pipe connections, and carbon filter replacement for optimal function.

Impeller stuck

Provides steps to free a stuck impeller by disconnecting power, removing the cover, and rotating the shaft.

Pressure switch stuck

Guides on removing, checking, cleaning, and lubricating the pressure switch unit for proper function.

Fault finding the product

The motor does not start when the level in the tank reaches the start level.

Troubleshoots motor failure to start, covering supply failure, fuse issues, stuck impeller, and pressure switch.

The motor hums but does not operate.

Diagnoses motor humming without operation, suggesting stuck impeller or motor/capacitor defects.

The pump runs but does not deliver the rated flow rate.

Troubleshoots low flow rate by checking for blockages in the pump, tank, vent hole, or outlet pipe.

Technical data

Supply voltage

Specifies the required supply voltage and frequency for the product.

Flow rate

States the maximum flow rate the pump can achieve.

System pressure

Defines the maximum pump head and system head, and the pressure limit for drainage.

Declaration of conformity

GB: EU declaration of conformity

States Grundfos' sole responsibility for the product's conformity with EU Council Directives.

Declaration of performance

GB: EU declaration of performance in accordance with Annex III of Regulation (EU) No 305/2011 (Construction Product Regulation)

Details product type, intended use, manufacturer info, and assessment system for CE marking.

Related product manuals