8.2 Operation
8.2.1 Minimum flow rate
To ensure the necessary cooling of the motor, the pump flow rate
should never be set so low that the cooling requirements in
section 5.4 Liquid temperatures/cooling cannot be met.
8.2.2 Frequency of starts and stops
9. Maintenance and service
All pumps are easy to service.
Service kits and service tools are available from Grundfos.
The pumps can be serviced at a Grundfos service centre.
If Grundfos is requested to service the pump, Grundfos must be
contacted with details about the pumped liquid, etc. before the
pump is returned for service. Otherwise Grundfos can refuse to
accept the pump for service.
Possible costs of returning the pump are paid by the customer.
Motor type Number of starts
MS 402
Minimum 1 per year.
Maximum 100 per hour.
Maximum 300 per day.
MS 4000
Minimum 1 per year.
Maximum 100 per hour.
Maximum 300 per day.
MS 6000
Minimum 1 per year
Maximum 30 per hour.
Maximum 300 per day.
MMS6
PVC
windings
Minimum 1 per year
Maximum 3 per hour.
Maximum 40 per day.
PE/PA
windings
Minimum 1 per year
Maximum 10 per hour.
Maximum 70 per day.
MMS 8000
Minimum 1 per year
Maximum 10 per hour.
Maximum 240 per day.
MMS 10000
Minimum 1 per year
Maximum 8 per hour.
Maximum 190 per day.
MMS 12000
Minimum 1 per year
Maximum 5 per hour.
Maximum 120 per day.
Franklin
Minimum 1 per year
Maximum 100 per day.
Warning
If a pump has been used for a liquid which is
injurious to health or toxic, the pump will be
classified as contaminated.