Fault finding
Fault Cause Remedy
1. Pump is not running. No
power supply.
System is switched off. Check the system controller.
A fuse in the installation is blown. Replace the fuse.
The circuit breaker has tripped.
Check the power connection and switch on the circuit
breaker.
Power supply failure. Check the power supply.
2. Pump is not running. Normal
power supply.
Controller is switched off. Check the controller and its settings.
Pump is blocked by impurities.
Remove impurities. Unscrew the deblocking screw at the
front of the pump. Deblock the pump from the front of the
control box with a screwdriver. Be aware of splashing hot
water.
Pump is defective. Replace the pump.
3. Pump runs at maximum
speed and cannot be
controlled.
No signal from signal cable.
Check if the cable is connected to the controller. If it is,
replace the cable.
4. Noise in the system. There is air in the system. Vent the system.
Differential pressure is too high.
Reduce the pump performance at the pump or external
controller.
5. Noise in the pump. There is air in the pump. Let the pump run. The pump vents itself over time.
Inlet pressure is too low.
Increase the system pressure or check the air volume in
the expansion tank, if installed.
6. Insufficient flow. Pump performance is too low. Check the external controller and the pump settings.
Hydraulic system is closed or system pressure is
insufficient.
Check the non-return valve and filter. Increase the
system pressure.