Data sheets
44
13
UPMXXL 25-120 180, 32-120 180 AUTO (GFJOC)
Electrical data, 1 x 230 V, 50/60 Hz
Technical data
Speed
P
1
[W] I
1/1
[A]
Settings
Min. 18 0.1 PP CP CC
Max. 180 0.4 3/AA 2/AA MAX
Dimensions
TM07 2014 2518
Pump type
Dimensions [mm]
Connections
Net weight
[kg]
L1 L2 L3 L4 B1 B2 B3 H1 H2 H3
UPMXXL 25-120 180 AUTO 180 90 45 65 117 50 75 55 104 82 G 1 1/2 3.2
UPMXXL 32-120 180 AUTO 180 90 45 65 117 50 75 55 104 82 G 2 3.4
System pressure: Max. 1.0 MPa (10 bar) Enclosure class: IPX2D
Minimum inlet pressure: 0.01 MPa (0.10 bar) at 95 °C liquid temperature Insulation class: H
Liquid temperature: -10 °C to +95 °C (TF 95) Equipment class: I
Motor protection: Overload protection Approval and marking: VDE, CE
0 1 2 3 4 5 6 7 8
Q [m³/h]
0
2
4
6
8
10
12
[m]
H
0
20
40
60
80
100
120
[kPa]
p
0.0 0.5 1.0 1.5 2.0 2.5
Q [l/s]
0 1 2 3 4 5 6 7 8
Q [m³/h]
0
40
80
120
160
200
[W]
P1
High Efficiency
EEI ≤ 0.23 Part 2
P
L, avg
≤ 94 W
Setting Max. H
nom
CP1 4 m
CP2 8 m
CC3 12 m
PP1 5 m
PP2 6.5 m
PP3 8 m
Setting Max. P1
nom
All curves 180 W