EasyManua.ls Logo

Grundfos UPS3 15-50/65 - Assembling the Installer Plug

Grundfos UPS3 15-50/65
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English (GB)
6
3.6 Assembling the installer plug
Step Action Illustration
1
Loosen the cable
gland and unscrew
the union nut in the
centre of the terminal
cover.
TM06 8542 0918
2
Detach the terminal
cover.
TM06 8543 0918
3
Pull the power cable
through the cable
gland and terminal
cover.
TM06 8544 0918
4
Strip the cable
conductors as
illustrated.
TM06 8545 0918
5
Loosen the screws
on the power supply
plug and connect the
cable conductors.
TM06 8546 0918 - TM06 8547 0918
6
Tighten the screws
on the power supply
plug.
TM06 8548 0918
L
PE
N
42 mm
32 mm
Ø 5.5 - 10 mm
0.5 - 1.5 mm
2
x 3
x 3
7
Refit the terminal
cover. See A.
Note: It is possible to
turn the power
supply plug on the
side for a 90 ° cable
entry. See B.
TM06 8549 0918 - TM06 8550 0918
8
Tighten the union
nut.
TM06 8551 0918
9
Tighten the cable
gland onto the power
supply plug.
TM06 8552 0918
10
Insert the power
supply plug into the
male plug on the
pump.
TM07 0376 1518
Step Action Illustration
B
A

Related product manuals