Chapter 5: Enclosure Installation
Installing the Heat Shield Wall for the Ladder Enclosure
An enclosure heat shield will be installed where a ladder or catwalk exists inside the heat enclosure area.
1. Install the catwalk support clip (15) to the vertical channel (41) above the lower right duct support
(12) using bolts (9) and nuts (33).
2. Install the ladder wall heat shield (26) to the vertical channels (41) using bolts (8) and nuts (4) in all
locations except for where the catwalk-platform bracket (13) is installed.
NOTE: Install the bolt heads to the inside of the grain column. The upper right duct support (3) is
installed between the ladder wall heat shield (26) and the vertical channel (42) using bolt (7)
and nut (8).
3. Install the catwalk-platform bracket (13) to the ladder wall heat shield (26) and vertical channel (41)
using bolts (9) and nuts (10).
NOTE: Install the bolt heads from the catwalk-platform bracket (13) side.
Figure 5-8 Ladder wall heat shield to vertical channel
3
Upper right duct support (GT1-2381)
13
Catwalk-platform bracket
4
5/16 x 3/4 in. flange bolt SS (S-8956)
15
Catwalk support clip
7
5/16 x 1 in. flange bolt SS (S-7447)
26
Ladder wall heat shield (see parts)
8
5/16 in. flange nut waxed (S-8452)
33
3/8 in. flange nut LRG (S-968)
9
3/8-16 x 1 in. flange bolt (S-7485)
41
Vertical channel
12
Lower right duct support (GT1-2382)
PNEG-2016 Tower Dryer Heat Reclaimer