FUNCTION GENERATOR -SERIES
INSTRUCTION MANUAL
l FIGURE 11
FUNCTION GENERATOR -SERIES
INSTRUCTION MANUAL
7. MAINTENANCE
The following instructions are used by qualified person only to avoid
electrical shock, do not perform any service other than contained in the
operation instructions unless you are qualified to do so.
7-1.Fuse Rating and type
If the fuse blows, the FUNCTION GENERATOR will not operate. Try
to determine and correct the cause of the blown fuse, then replace the fuse
with correct rating and type shown as below:
FUSE Rating and Type Rating Input
MODEL
115V 230V Watts
VA
GFG-8215A T0.315A 250V
T0.16A 250V
22 28
GFG-8216A T0.315A 250V
T0.16A 250V
25 32
GFG-8217A T0.315A 250V
T0.16A 250V
27 34
GFG-8219A T0.315A 250V
T0.16A 250V
29 36
GFG-8250A T0.315A 250V
T0.16A 250V
25 32
GFG-8255A T0.315A 250V
T0.16A 250V
29 36
WARNING: For continued fire protection, replace only
with 250V fuse of the specified type and rating, and
disconnect the power cord before proceeding fuse
replacement.