Dual Measurement Multimeter
GDM-9060/9061
USER MANUAL
GW INSTEK PART NO. 82DM-90610E01
ISO-9001 CERTIFIED MANUFACTURER

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the GW Instek GDM-906 Series and is the answer not in the manual?

GW Instek GDM-906 Series Specifications

General IconGeneral
CategoryDigital Multimeter
Continuity TestYes
Diode TestYes
Measurement FunctionsDC Voltage, AC Voltage, DC Current, AC Current, Capacitance, Frequency, Temperature, Diode, Continuity
DC Voltage Range100mV to 1000V
AC Voltage Range100mV to 750V
DC Current Range100µA to 10A
AC Current Range100µA to 10A
Resistance Range100Ω to 100MΩ
Temperature Range-200 °C ~ +200 °C
ConnectivityUSB
Power SupplyAC 100 V ~ 240 V, 50 Hz ~ 60 Hz

Summary

Safety Instructions

Safety Guidelines

Provides general safety guidelines for operating and handling the instrument.

Fuse Replacement

Step-by-step instructions for safely replacing AC source fuses.

Battery Replacement

Procedure for replacing the instrument's internal battery (CR2032).

Basic Measurement

AC/DC Voltage Measurement

Procedure for performing AC and DC voltage measurements.

AC/DC Current Measurement

Procedure for performing AC and DC current measurements using 3A and 10A terminals.

2W/4W Resistance Measurement

Instructions for performing 2-wire and 4-wire resistance measurements.

Continuity Test

How to perform continuity tests to check for conductive paths.

Diode Measurement

Procedure for testing diode forward bias characteristics.

Frequency/Period Measurement

How to measure the frequency or period of an input signal.

Capacitance Measurement

Procedure for measuring capacitance of a component.

Dual Measurement

Advanced Measurement

Relative Value Measurement

How to store a reference value and measure the delta between readings.

Hold Measurement

Function to retain current measurement data and update when it exceeds a set threshold.

Trigger Setting

Configuration for automatic or single triggering of measurements.

Math Measurement

Introduces math operations like dBm, dB, Compare, MX+B, 1/X, and Percent.

Compare Mode

Function to check if measurement data stays within specified upper and lower limits.

Digital I/O

System & Firmware

Firmware Update

Procedure for updating the instrument's firmware.

Menu Setting

Screenshot & Log

Capture

How to configure screenshot capturing mode and save files.

Remote Control

Web Control Interface

Accessing and using the web interface for instrument control and monitoring.

Command Syntax

Command Set

MEASure Commands

SCPI commands for performing various measurements on the primary display.

TRIGger Commands

SCPI commands for controlling measurement triggering and delay.

SYSTem COMMunication Commands

SCPI commands for configuring LAN, GPIB, and RS232 communication interfaces.

IEEE 488.2 Common Commands

Standard IEEE 488.2 common commands for instrument control.

Appendix

Fuse Replacement

Step-by-step guide on how to replace instrument fuses safely.

Battery Replacement

Procedure for replacing the internal battery (CR2032) of the instrument.

Specifications

Detailed technical specifications of the instrument.

GDM-9061 Section Specifications

Detailed specifications specific to the GDM-9061 model.

GDM-9060 Section Specifications

Detailed specifications specific to the GDM-9060 model.