128
MEASure<x>
Query
Description
Query Syntax
Parameter
(MANU mode)
No parameter needed for MANU
mode.
Parameter
(AUTO mode)
<x>
<NR1>1~16. Step number.
Return parameter
<string>
Returns the test status of the test
in the following format:
function, judgment or status, test
voltage, test current or resistance,
test time or ramp time
Function
ACW, DCW, IR, GB
Judgment
/Status
PASS, FAIL
VIEW
Test voltage
voltage+unit
Test current
/Test resistance
current+unit
resistance+unit
Test time
/Ramp time
T=time+S
R=time+S
Example
(in MANU mode)