GYSPOT ARCPULL 350
EN
• Put the pad (equipped with its cover) at the end of the earth rods and
screw in the 2 clamping screws. It is recommended to place the pad
with the clamping screws pointing down to the bottom of the gun to
keep the positioning markings clearly visible.
Note: The use of the gas protective pad and earth rods is not necessary
when welding a pull ring.
Positioning
marking
Clamping screw
USE OF THE RIVET EXTRACTION SET (ref : 064584 and clamp ref : 043787)
• Completely remove the stop screw from the dowel pin holder and
insert the dowel into the gas protection nozzle.
• Place the earth rods (supplied with the product) and adjust their
positions.
• Mount and screw the gas protection barrel on the pad.
• Mount and screw the pad thus equipped onto the rods.
• Connect the positive gun cable (red marking) to the texas
negative (-) of the generator.
• Connect the ground clamp to the positive (+) texas of the generator.
Screw
removed
Gas shielding gun locknut
Stud door
support
Stems
ERROR MESSAGE, ANOMALIES, CAUSES, SOLUTIONS
This device integrates a default management system. In the event of a default, error messages may be displayed.
Error code Meaning Causes Solutions
OVERHEATI NG DEFECT
Generator thermal
protection
Maximum duty cycle
reached.
Wait for the indicator to turn o before
resuming welding operations.
OVERVOL TAGE DEFECT
Mains voltage
default.
Mains power is out of
range or one phase is
missing.
Have your electrical installation chec-
ked by a qualied person. The voltage
between the phases must be between
208V AC and 240V AC.
PRESSED KEY
Keypad fault
A key on the keypad is
pushed when the machine
is switched on.
Ask a qualied person to check the key-
pad.