EasyManua.ls Logo

H3C MSR 20 - Page 115

H3C MSR 20
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MIM-2FXS/MIM-2FXO/MIM-2E&M and MIM-4FXS/MIM-4FXO/MIM-4E&M 115
Figure 131 E&M interface cable (Bell V 4-wire)
n
Because it is hard to determine the type of the switch to be connected and its
connectors, interface cables of MIM-2E&M/MIM-4E&M modules have to be
prepared according to the on-spot conditions or by the user. To ensure the EMC of
the Router, install a ferrite core near the connector of the prepared E&M module
interface cable by the router side.
Connecting the Interface
Cable
c
CAUTION:
Some measures are taken to protect MIM-2FXS/MIM-2FXO/MIM-2E&M and
MIM-4FXS/MIM-4FXO/MIM-4E&M. Still, you are recommended to install a
special lightning arrester at the input end of each connection cable to obtain
better lightning protection effect when the cable is led outdoors;
Table 75 Pinouts of E&M interface cable (Bell V 4-wire)
Router side
Signal at switch side (Bell V 4-wire) RJ-45 Pin RJ-45 interface signal
1 SB (negative power supply) -
2 E M
3 RING0 RING0
4 RING1 RING1
5 TIP1 TIP1
6 TIP0 TIP0
7 M E
8 SG (negative power supply
ground)
-
-48 V
PBX
Router
detect
M
E
7
on-hook
off-hook
on-hook
-48 V
on-hook
detect
M
E
2
off-hook
4- wire
6
T0
R0
T1
T1
R1 R1
R0
T0
4
5
3
4- wire
voice signal
-48 V
voice signal

Table of Contents