EasyManua.ls Logo

H3C MSR 20 - Connecting the Interface Cable

H3C MSR 20
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MIM-2VE1 Module 119
Interface Cable MIM-2VE1 interface cables are G.703-compliant 120-ohm balanced twisted pair
cables. At one end of the cable is a DB-15 male connector for the connection to
the Router, and at the other end is an RJ-45 connector for the connection to the
network.
Figure 134 E1 120-ohm balanced twisted pair cable
If the cable with the resistance of 75-ohm is needed, a 75-ohm-to-120-ohm cable
adapter (one end is BNC connector and the other end is RJ-45 connector) which is
illustrated in the following figure can be installed.
Figure 135 75-ohm-to-120-ohm adapter (with BNC connector)
c
CAUTION:
For the convenience of extending the connection of E1 120-ohm balanced
twisted pair cable, you can use network interface connector.
E1 120-ohm balanced twisted pair cable, network interface connector,
75-ohm-to-120-ohm adapter are optional accessories. Please select one when
purchasing a MIM-2VE1 module; by default, they are not provided.
For cable pinouts, see Low-End and Mid-Range Series Routers Cable Manual.
Connecting the Interface
Cable
c
CAUTION:
Some measures are taken to protect MIM-2VE1 module. Still, you are
recommended to install a special lightning arrester at the input end of its
connection cable to obtain better lightning protection when the cable is led
outdoors;

Table of Contents